BIOSHIELD
®
Commercial UV Sterilizer Installation and User's Guide
SECTION 3: INSTALLATION
6. Using the white retaining nut tightening tool
included with the UV system or a 1.5” socket or
an adjustable wrench, tighten the Quartz Sleeve
Retaining Nut until snug (5 ft. lb.). Over-tightening
can break the Quartz Sleeve Module on the
faceplate or the quartz sleeve inside the UV vessel.
7. The quartz sleeve is now properly assembled; you
are now ready to perform a Water Test See Page
14.