EasyManua.ls Logo

Pentair BIOSHIELD - Page 35

Pentair BIOSHIELD
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
BIOSHIELD
®
Commercial UV Sterilizer Installation and User's Guide
SECTION 11: SYSTEM SPECIFICATIONS
Vertical Series Dimensional Drawings
Dimensional Data
Electrical/Hydraulic Data
MODEL
BODY
SIZE
I/O PORT
FLANGE
SIZE
VESSEL DIMENSIONS (in Inches)
A B C D E F
VESSEL
HEIGHT w/
SAFETY
COVER
HEIGHT w/
MAINTENANCE
CLEARANCE
PORT
TO
PORT
MOUNTING
FLANGE
OD
CENTERLINE
TO PORT
FLANGE
FLOOR TO
INLET
522904 6 2 61 101 39 11 6
5
/8 6
1
/4
522905 6 2 61 101 39 11 6
5
/8 6
1
/4
522918 6 3 62 102 39 11 7
1
/8 6
7
/8
522919 6 3 62 102 39 11 7
1
/8 6
7
/8
522907 8 3 68 107 37
3
/4 13
1
/2 10
1
/2 9
7
/8
522920 8 4 68 107 37
3
/4 13
1
/2 10
7
/8 9
7
/8
522908 8 3 68 107 37
3
/4 13
1
/2 10
1
/2 9
7
/8
522921 8 4 68 107 37
3
/4 13
1
/2 10
7
/8 9
7
/8
522922 8 4 68 107 37
3
/4 13
1
/2 10
7
/8 9
7
/8
522935 8 6 68 107 37
3
/4 13
1
/2 9
5
/8 9
7
/8
522910 10 4 74 117 41
7
/8 16 11
7
/8 11
5
/8
522923 10 6 74 117 41
7
/8 16 10
5
/8 11
5
/8
522924 10 6 74 117 41
7
/8 16 10
5
/8 11
5
/8
522912 12 6 77 120 41
7
/8 19 15 13
5
/8
522913 12 6 77 120 41
7
/8 19 15 13
5
/8
MODEL INPUT WATTS
POWER ENCLOSURE
DIMENSIONS (H X W
X D)
AMPS MAX
LOAD @
120/230 VAC MAX PSI/BAR
MAX HEAD
LOSS PSI
522904 130 16" X 14" X 8.4" 2.1/1.0 50/3.4 2 - PSI
522905,522918 260 16" x 14" x 8.4" 3.9/2.0 50/3.4 2 - PSI
522919 390 16" x 14" x 8.4" 5.8/2.9 50/3.4 2 - PSI
522907,522920 390 16" x 14" x 8.4" 5.8/2.9 50/3.4 2 - PSI
522908,522921 520 20.2" x 16.3" x 8.4" 7.5/3.7 50/3.4 2 - PSI
522922,522935 650 24.6" x 20.2" x 10.6" 9.4/4.7 50/3.4 2 - PSI
522910,522923 780 24.6" x 20.2" x 10.6" 11.2 /5.6 50/3.4 2 - PSI
522924 910 24.6" x 20.2" x 10.6" 13.3/6.5 50/3.4 2 - PSI
522912 910 24.6" x 20.2" x 10.6" 13.3/6.5 50/3.4 2 - PSI
522913 1040 30.5" x 24.1" x 12.6" 15.0/ 7.5 50/3.4 2 - PSI