EasyManua.ls Logo

Pentair Jung Pumpen COMPLI 1010/4 BW - Page 70

Pentair Jung Pumpen COMPLI 1010/4 BW
80 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70
ENGLISHDEUTSCH
0197
JUNG PUMPEN GmbH - Industriestr. 4-6 33803 Steinhagen, Germany
13
452.11.1504 - 453.11.1504
EN 12050-1:2001
Fäkalienhebeanlage
compli 108/2 ME (JP09347/4) compli 108/2 M (JP09346/4)
compli 125/2 M (JP09877/4)
compli 300 E (JP09496/0)
compli 400 E (JP09770/5) compli 400 (JP00637/9)
compli 400 E (JP09324/5) compli 400 (JP09322/9)
compli 510/4 BW (JP09191/1) compli 525/2 BW (JP09194/1)
compli 515/4 BW (JP09192/1) compli 535/2 BW (JP09195/1)
compli 525/4 BW (JP09193/1) compli 508/2 ME (JP43128/0)
compli 508/2 M (JP43129/0) compli 525/2 M (JP43130/0)
compli 610/4 BW (JP09173/2) compli 625/2 BW (JP09176/2)
compli 615/4 BW (JP09174/2) compli 635/2 BW (JP09177/2)
compli 625/4 BW (JP09175/2)
compli 1010/4 BWE (JP09273/2) compli 1025/2 BW (JP09461/1)
compli 1010/4 BW (JP09829/5) compli 1035/2 BW (JP09462/1)
compli 1015/4 BW (JP09830/5) compli 1008/2 ME (JP43131/0)
compli 1025/4 BW (JP09831/5) compli 1008/2 M (JP43132/0)
compli 1025/2 M (JP43133/0)
compli 1210/4 BW (JP09168/2) compli 1225/2 BW (JP09171/2)
compli 1215/4 BW (JP09169/2) compli 1235/2 BW (JP09172/2)
compli 1225/4 BW (JP09170/2)
Sammeln und automatisches Heben von fäkalienfreiem und
fäkalienhaltigem Abwasser über die Rückstauebene
BRANDVERHALTEN NPD
WASSERDICHTHEIT, LUFTDICHTHEIT
- Wasserdichtheit Bestanden
- Geruchsdichtheit Bestanden
WIRKSAMKEIT (HEBEWIRKUNG)
- Förderung von Feststoffen Bestanden
- Rohranschlüsse Bestanden
- Mindestmaße von Lüftungsleitungen Bestanden
- Mindestfließgeschwindigkeit Bestanden
- Freier Mindestdurchgang der Anlage Bestanden
- Mindestnutzvolumen Bestanden
MECHANISCHE FESTIGKEIT
- Tragfähigkeit und strukturelle Stabilität des Sammel-
behälters für die Verwendung außerhalb von Gebäuden
NPD
- Strukturelle Stabilität des Sammelbehälters für die
Verwendung innerhalb von Gebäuden
Bestanden
GERÄUSCHPEGEL ≤ 70 dB(A)
DAUERHAFTIGKEIT
- der Wasserdichtheit und Luftdichtheit Bestanden
- der Hebewirkung Bestanden
- der mechanischen Festigkeit Bestanden
GEFÄHRLICHE SUBSTANZEN NPD
0197
JUNG PUMPEN GmbH - Industriestr. 4-6 33803 Steinhagen, Germany
13
452.11.1504 - 453.11.1504
EN 12050-1:2001
Lifting plant for wastewater containing faecal matter
compli 108/2 ME (JP09347/4) compli 108/2 M (JP09346/4)
compli 125/2 M (JP09877/4)
compli 300 E (JP09496/0)
compli 400 E (JP09770/5) compli 400 (JP00637/9)
compli 400 E (JP09324/5) compli 400 (JP09322/9)
compli 510/4 BW (JP09191/1) compli 525/2 BW (JP09194/1)
compli 515/4 BW (JP09192/1) compli 535/2 BW (JP09195/1)
compli 525/4 BW (JP09193/1) compli 508/2 ME (JP43128/0)
compli 508/2 M (JP43129/0) compli 525/2 M (JP43130/0)
compli 610/4 BW (JP09173/2) compli 625/2 BW (JP09176/2)
compli 615/4 BW (JP09174/2) compli 635/2 BW (JP09177/2)
compli 625/4 BW (JP09175/2)
compli 1010/4 BWE (JP09273/2) compli 1025/2 BW (JP09461/1)
compli 1010/4 BW (JP09829/5) compli 1035/2 BW (JP09462/1)
compli 1015/4 BW (JP09830/5) compli 1008/2 ME (JP43131/0)
compli 1025/4 BW (JP09831/5) compli 1008/2 M (JP43132/0)
compli 1025/2 M (JP43133/0)
compli 1210/4 BW (JP09168/2) compli 1225/2 BW (JP09171/2)
compli 1215/4 BW (JP09169/2) compli 1235/2 BW (JP09172/2)
compli 1225/4 BW (JP09170/2)
Collection and automatic lifting of wastewater without sewage and
wastewater containing faecal matters above the backflow level
REACTION TO FIRE NPD
WATERTIGHTNESS, AIRTIGHTNESS
- Water tightness Pass
- Odour tightness Pass
EFFECTIVENESS (LIFTING EFFECTIVENESS)
- Pumping of solids Pass
- Pipe connections Pass
- Minimum dimensions of ventilating pipes system Pass
- Minimum flow velocity Pass
- Minimum free passage of the plant Pass
-Minimum useful volume Pass
MECHANICAL RESISTANCE
- Load bearing capacity and structural stability of collec-
tion tank for use outside buildings
NPD
- Structural stability of collection tank for use inside buil-
dings
Pass
NOISE LEVEL ≤ 70 dB(A)
DURABILITY
- of structural stability Pass
- of lifting effectiveness Pass
- of mechanical resistance Pass
DANGEROUS SUBSTANCES NPD

Related product manuals