What to do if my Pentair Sta-Rite J Water Pump lost prime?
- CCharlotte KempAug 15, 2025
If your Pentair Water Pump has lost prime, you should reprime it and inspect the suction system for air leaks.

What to do if my Pentair Sta-Rite J Water Pump lost prime?
If your Pentair Water Pump has lost prime, you should reprime it and inspect the suction system for air leaks.
What to do if the flow through my Pentair Sta-Rite J Water Pump is obstructed?
If the Pentair Water Pump flow is completely or partially obstructed, locate and remove the obstruction. Refer to repair instructions for disassembly.
How to fix wrong rotation direction of Pentair Water Pump?
If the Pentair Water Pump is rotating in the wrong direction, reverse the rotation of a three-phase motor by interchanging any two leads. For reversing a single-phase motor, refer to the manufacturer’s instructions.
How to troubleshoot no voltage in Pentair Sta-Rite J?
If there is no voltage in the Pentair Water Pump power system, check the circuit breaker or fuses.
What to do if there is an obstruction in the suction piping of Pentair Sta-Rite J Water Pump?
If there is an obstruction in the suction piping of your Pentair Water Pump, locate and remove the obstruction.
What to do if Pentair Sta-Rite J pressure rating is exceeded?
If the pressure required by the system at the design flow rate exceeds the pressure rating of the Pentair Water Pump, compare the pump pressure and flow rate against the pump characteristic curve. Check for closed or partially closed valves in the discharge piping system. Alternatively, reduce the system pressure requirement or increase the pressure capability of the pump.
How to troubleshoot no voltage on one phase in Pentair Sta-Rite J Water Pump?
If there is no voltage on one phase of your three-phase Pentair Water Pump, check the phase voltage on the line side of the starter contactor and isolate the open circuit (circuit breaker, fuse, broken connections, etc.).
What to do if Pentair Water Pump pressure exceeds system requirements?
If the pressure rating of the Pentair Water Pump exceeds the pressure requirement of the system at the design flow rate, compare the pump pressure and flow rate against the pump characteristic curve. Also, inspect the discharge piping system for breaks, leaks, open bypass valves, etc. If necessary, reduce the flow rate by partially closing the discharge valve.
What to do if there are loose parts in Pentair Sta-Rite J Water Pump?
If there are loose parts in your Pentair Water Pump, inspect and repair them.
| Brand | Pentair |
|---|---|
| Model | Sta-Rite J Series |
| Category | Water Pump |
| Language | English |
General guidelines for supporting and sizing pump piping.
Instructions for increasing pipe size from the pump suction port.
Guidelines for increasing pipe size from the pump discharge port.
Step-by-step procedure for filling the pump and suction line with water.
Instructions for installing, grounding, and wiring the pump motor according to code.
Diagrams showing wiring connections for dual voltage and single voltage motors.
General information on pump service requirements and seal replacement.
Procedures for removing and installing the pump's shaft seal unit.