MODELS
671T 0294
H.P. MEDIUM HEAD MODELS
1/3 JMBT-56 JBMBT-56S
1/2 JMCT-56 JMC3T-56 JBMCT-56S JBMC3T-56S
3/4 JMDT-57 JMD3T-57 JBMD3T-57S
1 JMET-58 JME3T-58 JBMET-58S JBME3T-58S
1-1/2 JMFT-40 JMF3T-40 JBMFT-40S JBMF3T-40S
2 JMGT-41 JMG3T-41 JBMGT-41S JBMG3T-41S
2-1/2 – – JBMMGT-59S JBMMG3T-59S
H.P. HIGH HEAD MODELS
1/3 JHBT-61H JBHBT-61S
1/2 JHCT-61H JHC3T-61H JBHCT-61S JBHC3T-61S
3/4 JHDT-62H JHD3T-62H JBHDT-62S JBHD3T-62S JBH2DT-62S
1 JHET-63H JHE3T-63H JBHET-63S JBHE3T-63S
1-1/2 JHFT-51H JHF3T-51H JBHFT-51S JBHF3T-51S
2 JHGT-52H JHG3T-52H JBHGT-52S JBHG3T-52S
2-1/2 JHHG3T-53H JBHHGT-53S JBHHG3T-53S
OWNER’S MANUAL
60 CYCLE “J” and “JB” SERIES
CENTRIFUGAL PUMPS WITH TEFC MOTORS
© 2012 Pentair, Ltd. All Rights Reserved. S257 (11/15/12)
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.STA-RITE.COM
PH: 888-782-7483

Other manuals for Pentair Sta-Rite J Series

Questions and Answers

  • K
    Keith RodriguezAug 15, 2025
    What to do if my Pentair Sta-Rite J Water Pump lost prime?
    • C
      Charlotte KempAug 15, 2025
      If your Pentair Water Pump has lost prime, you should reprime it and inspect the suction system for air leaks.
  • S
    Samuel PearsonAug 18, 2025
    What to do if the flow through my Pentair Sta-Rite J Water Pump is obstructed?
    • J
      Jonathan DodsonAug 19, 2025
      If the Pentair Water Pump flow is completely or partially obstructed, locate and remove the obstruction. Refer to repair instructions for disassembly.
  • C
    calderongregoryAug 22, 2025
    How to fix wrong rotation direction of Pentair Water Pump?
    • J
      James PerezAug 22, 2025
      If the Pentair Water Pump is rotating in the wrong direction, reverse the rotation of a three-phase motor by interchanging any two leads. For reversing a single-phase motor, refer to the manufacturer’s instructions.
  • R
    Richard HawkinsAug 25, 2025
    How to troubleshoot no voltage in Pentair Sta-Rite J?
    • N
      Nathan LoweAug 26, 2025
      If there is no voltage in the Pentair Water Pump power system, check the circuit breaker or fuses.
  • S
    Sheila WatkinsAug 28, 2025
    What to do if there is an obstruction in the suction piping of Pentair Sta-Rite J Water Pump?
    • J
      Jesse JonesAug 28, 2025
      If there is an obstruction in the suction piping of your Pentair Water Pump, locate and remove the obstruction.
  • N
    nicholasknightSep 1, 2025
    What to do if Pentair Sta-Rite J pressure rating is exceeded?
    • J
      John DavisSep 1, 2025
      If the pressure required by the system at the design flow rate exceeds the pressure rating of the Pentair Water Pump, compare the pump pressure and flow rate against the pump characteristic curve. Check for closed or partially closed valves in the discharge piping system. Alternatively, reduce the system pressure requirement or increase the pressure capability of the pump.
  • B
    Benjamin FernandezSep 4, 2025
    How to troubleshoot no voltage on one phase in Pentair Sta-Rite J Water Pump?
    • R
      Ryan RodgersSep 4, 2025
      If there is no voltage on one phase of your three-phase Pentair Water Pump, check the phase voltage on the line side of the starter contactor and isolate the open circuit (circuit breaker, fuse, broken connections, etc.).
  • E
    Ethan StevensSep 7, 2025
    What to do if Pentair Water Pump pressure exceeds system requirements?
    • S
      Susan SpencerSep 7, 2025
      If the pressure rating of the Pentair Water Pump exceeds the pressure requirement of the system at the design flow rate, compare the pump pressure and flow rate against the pump characteristic curve. Also, inspect the discharge piping system for breaks, leaks, open bypass valves, etc. If necessary, reduce the flow rate by partially closing the discharge valve.
  • C
    crystal49Sep 12, 2025
    What to do if there are loose parts in Pentair Sta-Rite J Water Pump?
    • R
      Richard WellsSep 12, 2025
      If there are loose parts in your Pentair Water Pump, inspect and repair them.

Summary

Pump Models Overview

Piping and Connections

Piping - General

General guidelines for supporting and sizing pump piping.

Suction Pipe

Instructions for increasing pipe size from the pump suction port.

Discharge Piping

Guidelines for increasing pipe size from the pump discharge port.

Priming the Pump

Step-by-step procedure for filling the pump and suction line with water.

Electrical and Wiring

Wiring

Instructions for installing, grounding, and wiring the pump motor according to code.

Motor Wiring Connections

Diagrams showing wiring connections for dual voltage and single voltage motors.

Service and Maintenance

Pump Service

General information on pump service requirements and seal replacement.

Shaft Seal Service

Procedures for removing and installing the pump's shaft seal unit.

Trouble Causes and Remedy

Repair Parts List - J Series High Head

Repair Parts List - J Series Medium Head

Repair Parts List - JB Series Medium Head

Repair Parts List - JBH Series

Limited Warranty

Pentair Sta-Rite J Series Specifications

General IconGeneral
BrandPentair
ModelSta-Rite J Series
CategoryWater Pump
LanguageEnglish

Related product manuals