DMC Series Two - Stage
Horsepower Range: 1- 2 H.P.
60 Cycle
Single Phase Installations
Owner’s Record
Pump Model: _________________________________________________
Pump Serial No.: ______________________________________________
Pump Date Code: ______________________________________________
Motor H.P. _____________ Voltage ____________ Phase ___________
Date of Installation: ____________________________________________
Owner: ______________________________________________________
Installer: _____________________________________________________
Installer Phone Number: _________________________________________
Sta-Rite
293 Wright St., Delavan, WI 53115
PH: 888-782-7483 Orders Fax: 800-426-9446
WWW.STA-RITE.COM
© 2017 S690 (02/27/17)
Centrifugal Pumps
INSTALLATION AND
OPERATION MANUAL

Questions and Answers

  • S
    Steve ReynoldsAug 11, 2025
    What to do if my Pentair Sta-Rite DMC motor will not run?
    • J
      Jose BowenAug 11, 2025
      If your Pentair Water Pump motor won't run, first, make sure the disconnect switch is turned on. If it is on, check the fuse; a blown fuse could be the issue, so replace it. Also, inspect the circuit breaker and reset it if it's tripped. If these steps don't solve the problem, the starting switch might be defective and needs replacement. Remember to disconnect the power before replacing it. Finally, check all wires at the motor to ensure they are tightly connected and wired correctly. Disconnect power before checking and tightening any wiring.
  • A
    Angela MorrisonAug 27, 2025
    Why does my Pentair Sta-Rite DMC Water Pump motor run hot and overload kicks off?
    • A
      Andrew PierceAug 27, 2025
      If your Pentair Water Pump motor runs hot and the overload kicks off, or if the motor doesn't run and only hums, it could be due to incorrect wiring. Refer to the wiring instructions to ensure it's properly connected. Another potential cause is low voltage. Check the voltage being supplied to the motor. If the wire size is too small, install heavier wiring, referring to the electrical/wiring chart for guidance.
  • J
    Joseph TaylorSep 2, 2025
    What to do if Pentair Sta-Rite DMC Water Pump does not deliver water to full capacity?
    • J
      Jessica AcevedoSep 2, 2025
      If your Pentair Water Pump isn't delivering water to its full capacity, it could be due to several reasons. If the water level in the well is lower than expected, especially if it's more than 25 feet to the water, you might need a deep well jet. Corroded or limed steel piping can also cause excess friction, so replace it with plastic pipe if possible, or with new steel pipe. Insufficient pipe size can restrict water flow, so re-pipe using the size of the suction and discharge ports on the pump. Finally, the pump might not be getting enough water, in which case you should add additional well points.
  • T
    Terry AyalaNov 18, 2025
    Why is my Pentair Sta-Rite DMC Water Pump motor running but not delivering water?
    • B
      brittany27Nov 18, 2025
      If your Pentair Water Pump motor runs but no water is being delivered, several issues could be at fault. If this is a new installation, re-prime the pump according to the instructions. Check all connections on the suction line for air leaks, using soapy water or shaving cream to identify them. A leaking foot valve or check valve can also prevent water delivery, so consider replacing these. Ensure the pipe size matches the suction and discharge ports on the pump. If the pump has lost prime in an existing installation, check the suction line connections and shaft seal with soapy water. Also, make sure the water level isn't below the suction pipe inlet; if it is, lower the suction line and re-prime the pump. A plugged impeller, a stuck check valve or foot valve, frozen pipes, or a foot valve/...