2
MOUNTING
Mount the pump within 6 feet (Max) of
the tank for best performance and pump
life. The pump will pull farther, but the
farther it pulls the more work it does,
increasing vibration and noise, and
reducing the output and pump life.
Mount pump in a space of at least 1
cubic foot for adequate ventilation to
prevent overheating.
Pump may be mounted in any posi-
tion.
Mount pump for easy access for
cleaning strainer, maintenance and
service.
Mount pump on a solid surface to
prevent vibration and noise.
ELECTRICAL
The pump should be on a dedicated
(individual) circuit protected by the
specified fuse on the motor label.
A UL marine duty switch (ignition
protected) rated for 15 amps or higher is
recommended, and must interrupt cur-
rent flow on the positive (+ red) lead.
SHUT OFF POWER TO THE PUMP
WHEN LEAVING THE BOAT UNAT-
TENDED.
PLUMBING
Installation of a strainer is required to
prevent debris from entering the pump.
For noise and vibration reduction we
recommend at least 18 in. [.5 M] of
1/2" [13mm] I.D. flexible high-pressure
hose to both ports. The pump ports and
strainer should not be connected to
plastic or rigid pipe. This hose should
be anchored where it meets the hard
plumbing to reduce plumbing vibration.
INSTALLATION
The goal of installation is to provide a
quiet, easy to maintain installation with
good flow and low back pressure. This
can be accomplished with the following
guidelines:
Mount on a solid surface in an acces-
sible location for strainer cleaning and
pump maintenance.
Use flexible high-pressure hose on
the pump inlet and outlet [such as
SHURFLO Kit 94-591- 01]. The pump
ports and strainer should not be con-
nected to plastic or rigid pipe, or the
pump's normal motion will transmit
through rigid plumbing causing noise,
and possibly loosening or cracking
components.
Pump must use an adequate 50-mesh
strainer [such as SHURFLO 255 series
strainers].
Use a minimum of 1/2" [13mm] Inner
Diameter plumbing. Smaller ID plumb-
ing will cause cavitation, high back
pressure, low flow and noise.
Pump is designed for intermittent duty
only: Do not use these pumps for run-
ning a Reverse-Osmosis [RO] Filtration
System. High pressure continuous duty
usage will shorten the life of the pump
and is not covered under warranty.
Wire Size is 14 GA [2.5mm²] MINI-
MUM, 12GA [4mm²] is recommended—
See Wire Chart in Electrical Section for
minimum sizing.
Minimum power requirement is a 15
Amp circuit.
Reduce restrictions on inlet and out-
let. This includes small inner diameter
shut-off valves, winterizing valves and
elbows.
INSTALLATION GUIDELINES
Solid surface within 6 feet of tank
Accessible location
Minimize flow restrictions in the
system
Strainer on pump inlet
Properly sized wiring
Flexible hose on inlet and outlet -
Proper electrical protection
Minimize plumbing elbows and valves
Properly sized plumbing
Typical Pump Installation
Ft. [m] AWG [mm
2
]
0-20 [0-6] 14 [2.5]
20-50 [6-15] 12 4]
50-70 [15-21] 10 [6]
70-100 [21-30] 8 [8]
Minimum Wire Size for a 10% voltage drop on a 12VDC, 15 Amp
Circuit. Length is the distance from the power source to pump
and back to ground.