Do you have a question about the Pentair SHURFLO REVOLUTION 4008 Series and is the answer not in the manual?
Brand | Pentair |
---|---|
Model | SHURFLO REVOLUTION 4008 Series |
Category | Water Pump |
Language | English |
Highlights independent chambers, co-molded diaphragm, adjustable switch/bypass, self-priming, and thermal protection.
Details the pump's high performance, four independent chambers, self-priming capability, built-in check valve, and dry-run protection.
Provides guidance on mounting, plumbing, electrical connections, and fuse sizing for optimal pump setup.
Offers advice on settings, intermittent use, power management, strainer maintenance, and avoiding specific system uses.
Details optimal pump placement, access for maintenance, and securing methods to isolate vibration and noise.
Specifies the need for dedicated circuits, fuses, or circuit breakers as indicated on the motor label.
Advises on using strainers and flexible hoses for noise and vibration reduction in the plumbing system.
Explains intermittent duty, pressure regulation via bypass valve, and factors affecting performance like voltage.
Describes by-pass valve function and warns that adjustment should only be done by a qualified technician.
Outlines steps for cleaning potable water systems using bleach solution and flushing the system.
Provides steps to drain the pump and plumbing to prevent damage from freezing, voiding warranty if ignored.
Lists common problems like pump not starting, blowing circuits, not shutting off, and provides potential causes.
Identifies potential causes for priming failure, including clogged strainers, air leaks, or restricted plumbing.
Suggests causes for rapid cycling such as restrictive plumbing, flow restrictions, or incorrect shut-off pressure.
Explores causes for noise, including loose plumbing, restricted inlet, mounting surface issues, or air in the system.
Points to potential issues like loose screws, ruptured diaphragms, or pinched switch components.
Lists part numbers and descriptions for common pump repair components like upper assembly and valve assembly.
Covers the 2-year warranty for retail pumps, exclusions, and procedures for making warranty claims.