EasyManua.ls Logo

Pentair SHURFLO REVOLUTION 4008 Series User Manual

Pentair SHURFLO REVOLUTION 4008 Series
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page | 1
SHURFLO® REVOLUTION™ 3 GPM
115V AC PARK MODEL PUMP
MODEL SERIES 4008
New SHURFLO® 4008 REVOLUTION™ Designed for potable water applications
INSTALLATION TIPS
Mount on a solid surface within 6 feet of tank
Properly sized plumbing
Proper electrical protection
Properly sized wiring
Use proper fuse size
Strainer on pump inlet
Dry and accessible location
Minimize plumbing elbows and valves
Flexible high-pressure hose on inlet and outlet
No accumulator needed
FLUID MOTION TECHNOLOGIES 911-1022
BENEFITS
4 independent
chambers
Co-Molded diaphragm
Adjustable pressure
switch
Adjustable by-pass
Self-priming up to 6 feet
Thermally protected
CSA Listed
4008 REVOLUTION™
SHURflo’s 4008 pumps are equipped to deliver high
performance and reliability every time they are used.
SHURflo’s potable water pumps operate four
independent pumping chambers which allow the
pump to self-prime and lift water up to 6 feet. With
smooth flow and uninterrupted operation, the 4008
Revolution pumps include a built-in check valve to
prevent back flow into the tank. Each pump features
an adjustable pressure switch and by-pass and has
the capability to run dry without damage to the pump
or motor.
OPERATION TIPS
Do not adjust switch or bypass settings
without contacting customer service
Pump is design for intermittent operation
only
Turn off power to the pump when RV is
unattended
Maintain your strainer clean for ultimate
pump performance
Do not use pump for Reverse Osmosis
filtration system
Question and Answer IconNeed help?

Do you have a question about the Pentair SHURFLO REVOLUTION 4008 Series and is the answer not in the manual?

Pentair SHURFLO REVOLUTION 4008 Series Specifications

General IconGeneral
BrandPentair
ModelSHURFLO REVOLUTION 4008 Series
CategoryWater Pump
LanguageEnglish

Summary

4008 Revolution Pump Features and Operation

Pump Benefits

Highlights independent chambers, co-molded diaphragm, adjustable switch/bypass, self-priming, and thermal protection.

4008 Revolution Pump Description

Details the pump's high performance, four independent chambers, self-priming capability, built-in check valve, and dry-run protection.

Installation Tips

Provides guidance on mounting, plumbing, electrical connections, and fuse sizing for optimal pump setup.

Operation Tips

Offers advice on settings, intermittent use, power management, strainer maintenance, and avoiding specific system uses.

General Information and Guidelines

Mounting Recommendations

Details optimal pump placement, access for maintenance, and securing methods to isolate vibration and noise.

Electrical Requirements

Specifies the need for dedicated circuits, fuses, or circuit breakers as indicated on the motor label.

Plumbing Recommendations

Advises on using strainers and flexible hoses for noise and vibration reduction in the plumbing system.

Pump Operation and Maintenance

Pump Operation Details

Explains intermittent duty, pressure regulation via bypass valve, and factors affecting performance like voltage.

By-Pass Adjustment

Describes by-pass valve function and warns that adjustment should only be done by a qualified technician.

Sanitizing Procedure

Outlines steps for cleaning potable water systems using bleach solution and flushing the system.

Winterizing Instructions

Provides steps to drain the pump and plumbing to prevent damage from freezing, voiding warranty if ignored.

Troubleshooting Common Issues

Lists common problems like pump not starting, blowing circuits, not shutting off, and provides potential causes.

Troubleshooting Specific Problems

Will Not Prime / Sputters

Identifies potential causes for priming failure, including clogged strainers, air leaks, or restricted plumbing.

Rapid Cycling

Suggests causes for rapid cycling such as restrictive plumbing, flow restrictions, or incorrect shut-off pressure.

Noisy or Rough Operation

Explores causes for noise, including loose plumbing, restricted inlet, mounting surface issues, or air in the system.

Leaks from Head or Switch

Points to potential issues like loose screws, ruptured diaphragms, or pinched switch components.

Repair Kits and Warranty Information

Available Repair Kits

Lists part numbers and descriptions for common pump repair components like upper assembly and valve assembly.

Limited Warranty Details

Covers the 2-year warranty for retail pumps, exclusions, and procedures for making warranty claims.