2020-01
12
PMI360DV-F130-IU-V15
Installation
5.3 Electrical connection
Wire the electrical connections on the sensor as follows:
Electrical connection
1.
For the electrical connection to the sensor, use one of the cordsets with a 5-pin connector M12
x 1 listed in the Accessories chapter.
2. When routing the electric cables, make sure they are protected against physical damage.
3. Make sure that cables are routed at a sufficient distance from other current-carrying system
components. This is the only way to guarantee adequate protection from short circuits and/or
interfering signals. If required shielded cables can be used to help prevent electrical
interference.
4. Check that the wires are connected correctly before connecting the cordset to the sensor. On
Pepperl+Fuchs cordsets, the wire colors are assigned to the connecting pins in the connector
according to DIN EN 60947-5-2.
5. Attach the socket on the cordset to the connector on the sensor and tighten the union nut by
hand.
6. Switch on the operating voltage.
The "Power/Error" LED on the sensor lights up green if the actuator is already fitted and red
if the actuator is not yet fitted.
Wire colors are assigned to the connecting pins in the connector according to DIN
EN60947-5-2.
Note
The I/U LED may light up depending on the position of the actuator, as well.
Connector pin Function
1 +U
B
2 not connected
3 -U
B
4 not connected
5 Analog output I/U
Connecting pin Wire color
1 brown
2 white
3 blue
4 black
5 gray