7 Output function in normal operation
Example
Figure 7.1 Output function depends on the position of the actuator and the method used to program
the output.
1. Marking for angle position 0° (default setting is analog output I/U)
2. Start position of analog output I/U (example 20°)
3. End position of analog output I/U (example 110°)
4. Output signal
5. Angular range outside of analog measurement range. The function of the analog output
depends on whether the output assumes the function of a voltage or a current output (de-
pending on the load).
Current output:
If the measurement range is exceeded, the analog output value adopts the error signal 3.6
mA. The current output issues this fault current until the position of the actuator falls within
the programmed analog measurement range again.
Voltage output:
If the measurement range is exceeded, the analog output value retains the last displayed
value until the position of the actuator falls within the analog measurement range again
(shown in the example).
I/U1
360°270°180°90°0°
I/U1
I/U2
I/U2
I/U
4
2
1
3
55