Appendix A: Restoration of Factory Defaults
To restore the factory default settings on your Pepwave Surf SOHO unit, follow the steps below:
1. Locate the reset button on the back panel of the Pepwave Surf SOHO.
2. With a paperclip, press and keep the reset button pressed.
Hold for approximately 10 seconds for factory reset (Note: The LED status light shows in RED, until
the status light off and release the button).
After the Pepwave Surf SOHO finishes rebooting, the factory default settings will be restored.
Important Note
All previous configurations and bandwidth usage data will be lost after restoring factory
default settings. Regular backup of configuration settings is strongly recommended.
Appendix B: Overview of ports used by Peplink
SD-WAN routers and other Peplink services
Default
Port
Number
Usage Service Inbound/Outbound Default
Status
UDP 5246 Data flow InControl Outbound Enabled
TCP 443 HTTPS service InControl Outbound Enabled
TCP 5246 Optional, used
when TCP 443 is
not responding
InControl Outbound Enabled
TCP 5246 Remote Web Admin InControl Virtual
Appliance
Outbound Enabled