2
1…
7
07/2019
01/2020
SET SET
LC 60 120 250
LC 60 120 250
www.permausa.com
perma STAR VARIO - Quick Start Guide
1. Predefi ne installation / Select lubricant, discharge period + connecting parts
Remote mounting
for lube-points with vibration,
limited mounting space, high temperature
Direct mounting
2. Prepare lube-point
Clean lube-point
Remove grease fi tting
For remote mounting:
Prefi ll lube-point and any grease lines / connections
(use the same grease that is contained in the lubrication system)
For direct mounting:
Prefi ll lube-point and any connecting parts
(use the same grease that is contained in the lubrication system)
Assembly
Screw control unit onto LC unit until
arrow lines up (see enlargement)
Note
activation / exchange
date on label
Remove plug
3. Activation / Installation of lubrication system
Pressure check: Lube-point / all connecting parts
(refer to perma STAR VARIO installation guide for details)
Select discharge period
1 - 12 months
Mounting bracket
STAR Standard Duty
1-point G1/4 female
(109663)
Reducer G1/4
male x 1/4“ NPT
female (901000)
Reducer (will depend on
grease fi tting size)
Hose connector 1/4“ NPT
male for hose iØ 3/8“ -
push-on (901007)
Heavy Duty hose up to
260 °F / 127 °C iØ 3/8“
black (901006)
Hose connector
1/4“ NPT male for
hose iØ 3/8“ -
push-on (901007)
Support fl ange STAR
G1/4 male x G1/4
female (109420)
Select LC unit
60, 120, 250 cc
Average lubricant discharge chart (approximate)
2022/01 · Version: 1.3 · en · Art. No. 115018
Examples: Bearing lubrication
Reducer
Support fl ange STAR
Add reducer, support fl ange
and tubes (if required)
Add sealant