TDP074e.doc Rev.28.11.2016 Page6/29
PerrotREGNERBAUCALWGmbHIndustriestraße19‐29/D‐75382Althengstett/Germany
Tel.:+49‐7051‐162‐0/Fax:+49‐7051‐162
–133
E‐mail:perrot@perrot.de/Constructionteame‐mail:technik@perrot.de
3.3 Specialtools
VP3retainingringremovalhook Removeretainingring
RT17839
VP3retainingringpliers
Fitandreplaceretaining
ring
RT17844
VP3valvelifter Removevalve
RT25359
Faceholekey Pistonmotorcover
ZB98236
VP3flushinsert Flushmainline
RB25380
VP3assemblykeyfornozzle Changingnozzle
RB25189
TORX‐key forscrewsatthelid
ZB98289
4. Technicaldata
Recommendedoperatingpressure4to8bar
Permittedoperatingpressure 4to10bar
Thepressureatthesprinklermaynotexceed10bar
Connectionthread: G2“FT
Liquids:Water
Liquidtemperature: 40
o
Cmax.
Ambienttemperature: 60
o
Cmax.
Forfurtherdataseeseparatedatasheet.