Perrot VP3 VAC - Assembly, Set-up, and Installation; Installation Hazard Warnings; General Installation Instructions

Perrot VP3 VAC
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TDP074e.doc Rev.28.11.2016 Page7/29
PerrotREGNERBAUCALWGmbHIndustriestraße19‐29/D‐75382Althengstett/Germany
Tel.:+49‐7051‐162‐0/Fax:+49‐7051‐162
–133
E‐mail:perrot@perrot.de/Constructionteame‐mail:technik@perrot.de
5. Assembly,set‐upandinstallation
5.1 Hazardwarnings
Ifanyimpuritiesgetintothesprinkler,itispossiblethatthesprinklercould
bedestroyedandthatfitterscouldbeinjured.Thereforeflushouttheline
thoroughlybeforeconnectingthewatersupply.
Anyunexpectedemergenceofajetofwatercanleadtoseriousinjury.
Thereforemakesurethattheinstallationhasbeenfullycompletedbefore
turningonthewatersupply.
5.2 Installationinstructions
Thethreadconnectiononthepop‐upsprinkleris2"FT.
Forthethreadsealusehempandsealingcompound,e.g.FermitSpezialor
teflontape.
Thepop‐upsprinklershouldbefittedinaccordancewiththe'PerrotVP3pop‐
upsprinklerinstallationdiagram'(seenextpage).Inordertoavoidanyload
pressureonthemainline,youshoulddefinitelyuseaflexibleconnection.
Providingadrainagepitdirectlyconnectedtothedrainage,asshowninthe
installationdiagram,isverymuchrecommended.
Forscrewingintheconnectionjointthehousingorhousingedgeofthepop‐up
sprinklercanbefirmlyheldorclamped.