Adjustment
14 - 30
14.31 List of parameters
000 001 Maximum speed 500 – 2700 2700
This parameter is used to fix the max.
sewing speed (upper limit).
002 Sewing speed for start stitches
With this parameter the speeds for
the 5 start stitches are fixed.
Speed (spm) for start stitch no. 1 500 – 2700 500
Speed (spm) for start stitch no. 2 500 – 2700 900
Speed (spm) for start stitch no. 3 500 – 2700 2700
Speed (spm) for start stitch no. 4 500 – 2700 2700
Speed (spm) for start stitch no. 5 500 – 2700 2700
003 Locking/releasing seam patterns ON – OFF ON
This parameter is used to release (ON)
or lock (OFF) the individual seam
patterns (0 to 99) to be carried out in
the sewing mode.
004 Switch bobbin thread counter on/off ON – OFF OFF
Standard value (pieces per bobbin) 1 - 9999 1000
In the sewing mode, the bobbin thread
counter counts the pieces sewn
backwards from the standard value.
If the bobbin thread counter is
switched on, in the sewing mode a
signal is given when the value 0 is
reached.
006 Reversing after thread trimming ON – OFF OFF
Reverse position [°] 0 – 14 11
With this parameter it is possible to
switch the automatic reversing function
after thread trimming on or off. If the
reversing function is switched on, the
reverse position can be set by turning
the balance wheel. The access code is
necessary for this adjustment.
007 Starting point = scale reference point ON – OFF OFF
With this parameter it is possible to
choose whether the scale reference
point is the starting point (ON) or the
zero point (OFF).
Group Parameter Description Setting Set value