PG DRIVES TECHNOLOGY AC TRACTION – ADJUSTMENTS
The torque of the inner motor is halved to prevent a sudden increase in speed when steering rapidly beyond the 1.38 Dual Motor
Angle 2 setting.
The following graph shows an example of how these settings work with each other.
1.43 Standby Delay – (StdByDly)
This sets a period of time after which the Line Contactor will be de-energised if there is no drive activity and the seat or tiller switch
is open. When the seat or tiller switch is closed, the controller powers up, performs all necessary hardware and software checks
and closes the line contactor.
The adjustable range is 0 min to 10 min in 0.5 min steps.