23
Fault Code
Code
Description of
Fault Content
Solution
Corresponding
Parts
00
Undervoltage,
low battery
Please charge in time. Battery
01
Overvoltage, too
high battery
Needs to unplug the
charger.
Battery
02 Controller Fault
Controller needs to be
replaced.
Controller
03 MOS Tube Fault
After 15 minutes of
shutdown, restart to
conrm whether the fault
is resolved; if not, the
controller needs to be
replaced.
Controller
04
Hardware
Communication
Fault
Check the connection
line between the
controller and the
display, if the connection
is nommal, but the fault
is not resolved, please
call the manufacturer.
Controller/
Display
05 Hall Fault
Check the Hall wire
between the controller
and the motor. lf the
connection is nommal.
but the fault is not
resolved, the motor
needs to be replaced.
Motor
06 Accelerator Fault
Check the accelerator
shift connection cable,
if the connection is
nommal, whether the
fault is resolved; if not,
replace the shift.
Accelerator