Step 5. Remove the sclar and power board.
- Disconnect the 1505,1502,1413 and 4 backlight cables
as shown in Fig.13
- Remove the scaler and power board as shown in Fig.14
Fig.14
**************************************************************************************
***************************************************************************************
In warranty, it is not allowed to disassembly the LCD panel, even the
backlight unit defect.
Out of warranty, the replacement of backlight units is a correct way
when the defect is caused by backlight (CCFL, Lamp).
Fig.15
Mechanical Instruction
Fig.12
4 backlight cables
1413 to Panel
1502 to Power board
1505 to Control board
Fig.13
Panel