4-17 PL19.00-B_DC
3. How to Attach Adjunctive Equipment
There are no Cell Cushion, etc. attached on the new
Front Cabinet to be replaced with.
Apply adjunctive equipment such as Cell Cushion by
consulting the following, then assemble the Front
Cabinet.
1. Grand Tape (Top side)
Attach the Grand Tape on the top side of the Front
Cabinet.
2. Grand Tape (Left/ Right)
Attach the Grand Tape on the l
eft and right
side of
the Front Cabinet.
3. Gasket
Attach the Gasket over the Grand Tape.
4. Cell Cushion (Top side)
Attach the Cell Cushion over the Grand Tape.
5. Cell Cushion (Left/ Right)
Attach the Cell Cushion
over the Grand Tape
.
CAUTION #
When turning over, do not twist the LCD panel
before tightening all screws on the front cabinet.
A Grand Tape U is pasted
onto rib which its edge must
over than rib L/R (blue line).
Either it starts on left or right
no problem.
Exceed Front Cabinet edge
is NG
A Grand Tape U is pasted
onto rib which its edge must
over than rib L/R (blue line).
Either it starts on left or right
no problem.
Exceed Front Cabinet edge
is NG
A Grand Tape U is pasted
onto rib which its edge must
over than ri
b L/R (blue line).
Either it starts on left or right
no problem.
Exceed Front Cabinet edge
is NG
A Grand Tape U is pasted
onto rib which its edge must
over than rib L/R (blue line).
Either it starts on left or right
no problem.
Exceed Front Cabinet edge
is NG
At the concave area, a Grand Tape U
should be pasted and aligned properly
following the shape.
At the concave area, a
Grand Tape U
should be pasted and aligned properly
following the shape.
Front cab
edge
Concave area
Gasket must be pasted inside designated concave area and
must be on a Grand Tape at left and right bottom side.
Riding on the rib is NG
Gasket must be pasted inside designated concave area and
must be on a Grand Tape at left and right bottom side.
Riding on the rib is NG
A Cell C
ushion U is pasted onto rib which starts at blue line.
Either it starts on left or right no problem.
Pasting error +/- 2mm
Exceed Front Cabinet edge is NG
A Cell Cushion U is pasted onto rib which starts at blue line.
Either it starts on left or right no problem.
Pasting error +/- 2mm
Exceed Front Cabinet edge is NG
A Cell Cushion LR is pasted
onto rib which starts at blue line.
Either pasting starts from top
or bottom is no problem.
Pasting error +/- 2mm
Exceed Front Cabinet edge is NG
A Cell Cushion LR is pasted
onto rib which starts at blue line.
Either pasting starts from top
or bottom is no problem.
Pasting error +/- 2mm
Exceed Front Cabinet edge is NG