Mechanical Instructions
EN 14 Q549.6E LA4.
2009-May-29
4.3.9 LCD Panel
Refer to Figure 4-7
and Figure 4-8 for details.
1. Follow steps described in section 4.3.8 IR & LED Board
2. Remove the screws that secure the rim [8].
3. Remove both AmbiLight units.
4. Remove both AmbiLight subframes [9].
5. Remove the outer rim (with the touchable controls) by
lifting the bottom part and moving the entire rim upwards.
6. Before sending in the LCD Panel, remove all remaining
subframes!
4.4 Set Re-assembly
To re-assemble the whole set, execute all processes in reverse
order.
Notes:
• While re-assembling, make sure that all cables are placed
and connected in their original position.
• Pay special attention not to damage the EMC foams in the
set. Ensure that EMC foams are mounted correctly.