TEMPERATURES
ORIENTATION
DISTANCES
A temperature sensor must be installed inside the cabinet between two driver boxes.
The temperature measured by the sensor has to be lower than 45°C.
We recommend a cabinet protected against solar action.
MAXIMUM Relative Humidity:
95% -> Storage & Transport
90% -> Operating (no condensation allowed)
The distances between driver box-
es or wall have to be higher than:
Each driver box in the
cabinet has to be in
vertical position
Item Distance
1* Min 50mm
2** Min 80mm
3** Min 50mm
4** Min 150mm
5* Min 200mm
Cabinet
5
4
2
3
1
Installation of drivers boxes on cabinet
An active cooling can be added in the cabinet to guarantee a maximum temperature of
45°C all along the year
Cables
A thermal study must be done in order to respect Tc of the drivers below Tc max
Tc of the driver must be checked
* not mandatory if there is an active cooling inside the cabinet. The
cooling study must be done
** Recommended distances, but the temperatures inside the cabinet
and Tc driver must be checked
13/24