Installation of driver boxes on the bracket or in horizontal position
TOP
BOTTOM
Breathers cannot be exposed directly to water
×
BVP518 Mains voltage Max Nr luminaires
connected
MCB 16A A type 220V-240V 2
MCB 16A B type 220V-240V 2
MCB 32A A type 220V-240V 5
MCB 32A B type 220V-240V 5
MCB 16A A type 380V-400V 5
MCB 16A B type 380V-400V 5
Maximum number of luminaires to be connected to standard circuit breakers (fuse)
BVP528 Mains voltage Max Nr luminaires
connected
MCB 16A A type 220V-240V 1
MCB 16A B type 220V-240V 1
MCB 32A A type 220V-240V 3
MCB 32A B type 220V-240V 3
MCB 16A A type 380V-400V 3
MCB 16A B type 380V-400V 3