Diagnostic Software
EN 16 DVDR615, MRV6405.
Error messages D&S program
Figure 5-6a
Error messages D&S program
Figure 5-6b
In these cases, the boot EEPROM of the Digital Board does not
contain the required string with the hardware information. To
update the Digital Board with the correct string, nucleus 1226
must be executed.
See next section 'Diversity String Input'.
There can also be the next error message.
Figure 5-6c
Enter "Y" to program a safe string. With this automatically
generated string the board will work in principle but it has to be
checked if all board settings were detected correctly.
Diversity String Input
4. Execute nucleus 1226 to enter the string. Please see
chapter 8.4 for details
Nucleus 1226 execution with string
Figure 5-7
5. To check if the hardware info is filled correctly, you can
execute nucleus 1228.
Nucleus 1228 info example
Figure 5-8
6. Exit the 'Terminal' program.
7. Reboot the DVD recorder to allow the software to start.