PDS-150e Product Guide 5
Electrical Conguration Guidelines
EachPDS-150epower/datasupplyaccommodatesuptothreeColorBlast12
fixtures,orsixC-Splash,ColorBlast6,orColorBurst6fixtures.
EachPDS-150edevicemustbeinstalledonadry,unobstructed18x18in(457x457
mm)areathatallowsairtomovefreelyaroundthedevice.Startupandoperating
temperaturesareratedto122°F(50°C).Exceedingthistemperaturelimitmay
causedevicedamageorfailure.
Data Conguration Guidelines
WhenselectingmountinglocationsforthePDS-150edevicesinyourinstallation,
keepcableandfixturerunlengthlimitsinmind:
• InEthernetnetworks,maximumdatacableslengthsare328ft(100m)between
Ethernetdeviceswithoutarepeater.
• InDMXnetworks,maximumdatarunlengthsare1000ft(305m).The
maximumnumberofPDS-150edevicesthatcanbeconnectedinseriesis32.We
recommendusingtheon-boardDMXrepeaterforrunsofmorethan32
PDS-150edevicesconnectedinseries.However,forrunlengthsoflongerthan
1000ft(305m),werecommendusingathird-party,commercially-availableDMX
repeater.
PDS-150eallowsyoutoinputEthernetnetworkdataandoutputaDMXsignalto
downstreamdevicesandxtures.
Inspect PDS-150e and Accessories
CarefullyinspecttheboxcontainingthePDS-150eandthecontentsforanydamage.
Assemble Additional Items
ThefollowingadditionalitemsarerequiredtomountandconnectthePDS-150e:
• Fourmountingscrewssuitableforthemountingsurface
• Theincluded14coverscrewsandlockwashers
• Theincludedsix3-pinconnectors,andone5-pinconnector
• OnewirenutperC-Splash2xture
• OneinsulatedringorspadecrimpterminalperC-Splash2xture
• One8in(203mm)connectingwireperC-Splash2xture
• Theincludedthreepushwireconnectors
• Theincludedcablestrainreliefconnector
• CAT5eorbetterdatacable,asrequired
• Ifrequiredbylocalelectricalcodes,installationsusingUStradesizeconduit
require11/2inNPTconduitandttingsforpower,and1/2inNPTconduitand
ttingsfordata
• Ifrequiredbylocalelectricalcodes,installationsusingmetricsizeconduitrequire
PG42mmconduitandttingsforpower,andPG13.5mmconduitandttingsfor
data
• 3-conductorcopperwireforpowerconnections,asrequired.Fixtureconnections
alsorequire3-conductorcopperwire,withtheexceptionofC-Splashxtures,
whichrequire4-conductorwire.Standard12AWG(3.31mm
2
)strandedwireis
recommended.
• Screwdrivers,wirestrippers,andothertoolsasneeded
DMXmaximumdatarunlength
PDS-150eController
328 ft (100 m) Max
Controller
1000 ft (305 m) Max
PDS-150e
Ethernetmaximumdatacablelength
Includedinthebox
PDS-150epower/datasupply
(6)3-pinconnectors
5-pinconnector
(14)6-32x1/4Phillipsheadscrews,lockwashers
(3)4amp250VACfuses(spares)
Cablestrainreliefconnector
(3)Pushwireconnectors
InstallationInstructions