WelcomeEye Connect 2 / Touch / V1
2. Conguring the intercom (see g. 1, g. 2 or g. 3)
a. Conguring the intercom number:
Place switch 2 on the left on intercom no. 1 and on the right on intercom no. 2.
b. Conguring the number of families:
Place switch 1 on the left for single family mode and on the right for two family mode.
Important: The switch positions must be changed before powering the intercom.
c. Intercom volume settings:
Turn the volume control with a Phillips head screwdriver to adjust the intercom volume.
d. Conguration of the RFID function:
The RFID function enables openings to be managed using badges.
1) Programming (or resetting) the administrator badges:
When switching on the device for the rst time, the badges must be congured in the
following order:
1. Press the reset button at the back of the intercom panel for ve seconds, the intercom
panel will emit six short beeps.
2. Swipe the yellow administrator badge, one short beep conrms the programming.
3. Swipe the blue badge, one short beep conrms the programming.
4. Swipe the red badge, one long beep conrms that the administration badges have been
programmed.
2) Add one or more user badges:
1. Swipe the blue badge, four long beeps conrm the activation of the programming mode.
2. Swipe all user badges (grey) to be activated; one short beep conrms the programming
of every badge presented.
3. Once all of the badges have been programmed, wait 10 seconds. One long beep conrms
the end of the programming process.
3) Remove one or more user badges:
1. Swipe the badge (red); 4 long beeps conrm the activation of the programming mode.
2. Swipe all user badges (grey) to be deactivated; one short beep conrms the deactivation
of every badge presented.
3. Once all badges have been deactivated, wait 10 seconds. One long beep conrms the
end of the programming process.
4) Remove all user badges:
1. Swipe the administrator badge (blue); 4 short beeps conrm the activation of the
administration mode.
2. Swipe 1 user badge (grey) that has already been added; one short beep indicates that all
user badges have been deactivated.
5) Using the badges:
To open the electric strike plate, quickly swipe your pre-programmed grey user badge on
the RFID reading eld. One short beep conrms the opening of the electric strike plate.
To open the gate motor, hold the badge in front of the RFID scan area for 3 seconds. Two
short beeps indicate that the gate is opening.
6) Replacing a badge
RFID badges do not have predened functions. It is the programming step that sets the

Other manuals for Philips WelcomeEye Connect 2