EasyManua.ls Logo

Phocos Any-Grid PSW-H-5kW-230/48V User Manual

Phocos Any-Grid PSW-H-5kW-230/48V
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Phocos Any-Grid series
Pure Sine Wave Hybrid Inverter Ch arger with
MPPT Solar Charge Controller
PSW-H-8kW-230/48V
PSW-H-5kW-230/48V
PSW-H-3kW-230/24V
PSW-H-6.5kW-120/48V
PSW-H-5kW-120/48V
PSW-H-3kW-120/24V
User and Installation Manual
English
For further languages see
Für weitere Sprachen siehe
Pour autres langues voir
Para otros id iomas ver
对于其他语言请参阅
www.phocos.com

Other manuals for Phocos Any-Grid PSW-H-5kW-230/48V

Questions and Answers:

Phocos Any-Grid PSW-H-5kW-230/48V Specifications

General IconGeneral
Output Power5000 W
DC Input Voltage48 V
AC Output Voltage230 V
Battery Voltage Range40-60V
MPPT Chargers1
Max PV Input Power6000 W
Max PV Input Voltage500V
ModelAny-Grid PSW-H-5kW-230/48V
Rated Power5000 W
CommunicationRS485, CAN
TypeHybrid Inverter
ProtectionOverload, Short Circuit, Over Temperature

Summary

Important Safety Information

Regulatory Information

Installation

Mounting the Unit

Provides instructions and safety warnings for securely mounting the Any-Grid unit on a wall.

Battery Connection

Guides on connecting the battery, including cable sizing, fuse rating, and polarity warnings.

AC Input and AC Output Connection

Instructions for connecting AC source and loads, including breaker requirements and wiring precautions.

PV Connection

Details how to connect PV modules, including cable sizing, breaker ratings, and voltage/current specifications.

Installing Multiple Units: Parallel, Split Phase, or 3-Phase Configuration

Explains how to install multiple Any-Grid units in parallel, split-phase, or 3-phase configurations.

Commissioning Multi-Unit Systems

Single-Phase Parallel Commissioning

Step-by-step guide for commissioning multiple units in a single-phase parallel configuration.

3-Phase System Commissioning

Guide for commissioning units in a 3-phase configuration, detailing settings for each phase.

Split-Phase (2-Phase) System Commissioning

Instructions for commissioning units in a 2-phase split-phase configuration.

Operation

Inverter Power ON/OFF

Details the procedure for turning the inverter's AC output on and off using the ON/OFF switch.

Device Operation Settings Navigation

Introduces how to access and navigate the unit's settings menus for configuration.

AC Output Source Priority Configuration

Configures the priority of power sources (Utility, Solar, Battery) for supplying AC output loads.

Maximum Total Battery Charging Current Setting

Sets the combined maximum charging current from AC and solar sources for battery health.

Battery Type Configuration

Selects the battery type (UPS, AGM, Pylontech, etc.) to optimize charging and protection.

Solar Power Feed-in to Grid Setting

Configures grid feed-in functionality, requiring a PIN code for activation and legal checks.

Maximum AC Source Charging Current Setting

Limits the maximum charging current from the AC source to protect certain battery types.

Grid/Off-Grid Switchover Voltage (SBU Priority)

Sets the battery voltage threshold for switching between Grid and Off-Grid modes in SBU priority.

Battery Charger Source Priority Configuration

Configures which power sources (Solar, Utility) are prioritized for charging the battery.

Boost Battery Charging Voltage Setting

Sets the voltage level for the boost charging phase of the battery.

Floating Battery Charging Voltage Setting

Sets the voltage level for the floating charging phase of the battery.

Battery Equalization Voltage Setting

Sets the voltage for battery equalization to prevent sulfation and balance cells.

Battery Equalization Duration Setting

Sets the duration for which the equalization voltage is held before the floating phase.

Battery Equalization Timeout Setting

Sets the timeout for equalization if the target voltage is not reached.

Fault Reference Codes

Warning Codes

Troubleshooting Common Issues

Unit Shuts Down During Start-up

Addresses issues where the unit automatically shuts down during the initial startup process.

No Response After Power On

Troubleshoots scenarios where the unit does not respond or show any indication after being powered on.

AC Source Present, Unit Operates in Off-Grid Mode

Diagnoses why the unit operates in Off-Grid mode when an AC source is available.

Internal Relay Repeatedly Switches On/Off

Solves the issue of the internal relay repeatedly switching on and off after the unit is turned on.

Buzzer Beeps Continuously With Red LED

Addresses troubleshooting when the buzzer beeps continuously and the red LED is on, indicating faults.

Specifications Overview

Warranty Information

Related product manuals