RAD-...-IFS
168 / 198
PHOENIX CONTACT 105542_en_05
Conformity with EMC directive 2014/30/EU (RAD-2400-IFS and RAD-868-IFS)
Immunity to interference according to EN 61000-6-2
Electrostatic discharge EN 61000-4-2
Contact discharge ±6 kV (test intensity 3)
Air discharge ±8 kV (test intensity 3)
Indirect discharge ±6 kV
Comment Criterion B
Electromagnetic HF field EN 61000-4-3
Frequency range 26 MHz ... 3 GHz (test intensity 3)
Field strength 10 V/m
Comment Criterion A
Fast transients (burst) EN 61000-4-4
Input ±2 kV (test intensity 3)
Signal ±2 kV
Comment Criterion B
Surge current loads (surge) EN 61000-4-5
Input ±0.5 kV (symmetrical)
±1 kV (asymmetrical)
Signal ±1 kV (asymmetrical)
Comment Criterion B
Conducted interference EN 61000-4-5
Frequency range 0.15 MHz ... 80 MHz
Voltage 10 V
Comment Criterion A
Noise emission according to EN 61000-6-4 (RAD-2400-IFS and RAD-868-IFS)
Emitted radio interference according to EN 55011 EN 55016-2-3 Class A, industrial area of application
Criterion A Normal operating behavior within the specified limits
Criterion B Temporary adverse effects on the operating characteristics that the device corrects automatically.
RED directive 2014/53/EU RAD-2400-IFS RAD-868-IFS
EMC - immunity to interference (electromagnetic compat-
ibility of wireless systems)
EN 61000-6-2, generic standard for industrial environments
Safety - protection of personnel with regard to electrical
safety
EN 60950
Health - limitation of exposure of the population to electro-
magnetic fields
EN 62311
Radio - effective use of the frequency spectrum and avoid-
ance of radio interference
EN 300328 EN 300220