PSEN cs4.1 M12/8-1.5m
Operating Manual PSEN cs4.1 M12/8-1.5m
1003810-EN-07
| 29
6. Insert the screw into the actuator’s hole and position the screw at the hole on the
mounting surface.
To screw on the actuator, use the supplied plastic M3 countersunk screw.
When using a screw mad from metal the operating distance change, please note the
Warning [ 24].
7. Press on the actuator for at least3seconds with approx. 50N.
After this time, an adhesive force of approx. 50% is achieved. The full adhesive force is
achieved after 72 hours at an ambient temperature of at least 20°C.
8. Check the adhesive force of the glue after 10 minutes.
The actuator must no move when pressed sideways.
9. Tighten the M3 plastic screw to 0.1 Nm.