System Options
PIMA Electronic Systems 23
9.6 Auto Arming
User Menu
System Options
Auto Arming
The alarm system can be auto armed without the need to enter any code. Auto arming can
be in
Away
or
Home
modes. If partitions are in use, each partition can be armed in a different
time and have a separate no-movement period.
There are two auto-arming options:
Timed: daily, at a certain time.
No Movement: when no movement is detected in any of the detectors for a given period,
probably because the premises is vacant and the alarm system was not armed
14
.
When the auto-arming starts, the keypad buzzer sounds a series of beeps for a period of 45
seconds, after which the exit delay runs and the system is armed. If a user stops the process
by entering a user code, FORCE will try to re-arm itself, according to the parameters you set in
this menu.
The technician can set the alarm system to bypass open zones on auto-arming (they will be
reinstated when the system is disarmed).
1) Timed: select a partition (or stay in Partition 1 for no-partition system):
Definition
Description
Daily Hour
For every day of the week, set the time of the day for auto-arming.
Retry Interval
If a user stops the auto-arming process by entering a user code, set an
interval in hours and minutes for arming retries. FORCE will try to re-arm
itself according to the interval and the retry period (next).
Retry Period
If a user stops the auto-arming process by entering a user code, set the
period in hours (1-12) for the FORCE to re-arm itself. If you do not set any
period, FORCE will try to re-arm itself until midnight of the same day, in
accordance with the previous Retry Interval.
Arming Mode
Select in which arming mode FORCE will be auto-armed: Away or Home 1-4.
2) No-movement:
a. Select a partition (or stay in Partition 1 for no-partition system) and set the time in
minutes (up to 255), that if no detector detects any movement at all, the auto-arming
process will start.
b. Period: no-movement time in minutes (up to 255).
c. Arming Mode: see above.
3) Timed-All Partitions: apply the definitions of partition #1 to all partitions.
4) No-Movement-All Partitions: apply the definitions of partition #1 to all partitions.
9.7 Reset Smoke Detector
User Menu
System Options
Reset Smoke Detector
When a smoke detector detects smoke, it remains in detection mode and cannot reset itself. If
the detector was activated because of the presence of smoke, read its instructions guide. If
there was no smoke, press here to reset the detector.
14
Someone may be sleeping also.

Other manuals for Pima FORCE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pima FORCE Series and is the answer not in the manual?

Pima FORCE Series Specifications

General IconGeneral
BrandPima
ModelFORCE Series
CategorySecurity System
LanguageEnglish

Related product manuals