14 Programming the Hunter-Pro series with an LED keypad
Parameter Address
Zone 2 Type 233
Zone 3 Type 234
Zone 4 Type 235
Zone 5 Type 236
Zone 6 Type 237
Zone 7 Type 238
Zone 8 Type 239
Zone 9 Type 240
Zone 10 Type 241
Zone 11 Type 242
Zone 12 Type 243
Zone 13 Type 244
Zone 14 Type 245
Zone 15 Type 246
Zone 16 Type 247
Zone 1 Characteristics (byte 1)
(1=Bypass 2=N.O 3=24 Hrs
4=Home 1 5=Home2 6=Entry
Delay 7=Entry Follower 8=Second
Entry Delay Time 9=EOL
Protected)
248
Zone 1 Characteristics (byte 2)
(10=Conditioned Zones 11=Double
Knock 12=Enable User Bypass)
249
Zone 2 Characteristics (byte 1) 250
Zone 2 Characteristics (byte 2) 251
Zone 3 Characteristics (byte 1) 252
Zone 3 Characteristics (byte 2) 253
Zone 4 Characteristics (byte 1) 254
Zone 4 Characteristics (byte 2) 255
Zone 5 Characteristics (byte 1) 256
Zone 5 Characteristics (byte 2) 257
Zone 6 Characteristics (byte 1) 258
Zone 6 Characteristics (byte 2) 259
Zone 7 Characteristics (byte 1) 260
Zone 7 Characteristics (byte 2) 261
Zone 8 Characteristics (byte 1) 262
Zone 8 Characteristics (byte 2) 263
Zone 9 Characteristics (byte 1) 264
Zone 9 Characteristics (byte 2) 265
Zone 10 Characteristics (byte 1) 266
Zone 10 Characteristics (byte 2) 267
Zone 11 Characteristics (byte 1) 268
Parameter Address
Zone 11 Characteristics (byte 2) 269
Zone 12 Characteristics (byte 1) 270
Zone 12 Characteristics (byte 2) 271
Zone 13 Characteristics (byte 1) 272
Zone 13 Characteristics (byte 2) 273
Zone 14 Characteristics (byte 1) 274
Zone 14 Characteristics (byte 2) 275
Zone 15 Characteristics (byte 1) 276
Zone 15 Characteristics (byte 2) 277
Zone 16 Characteristics (byte 1) 278
Zone 16 Characteristics (byte 2) 279
Burglary Response 280
Panic Response 281
Fire Response 282
Duress/Hold-up Response 283
Medical Response 284
Anti Mask Response 285
Special Burg. 1Response 286
Special Burg. 2 Response 287
Silent Panic Response 288
Special Fire Response 289
Burglary Type Sensitivity (X50ms) 290
Panic Type Sensitivity (X50ms) 291
Fire Type Sensitivity (X50ms) 292
Duress/Hold-up Type Sensitivity
(X50ms)
293
Medical Type Sensitivity (X50ms) 294
Anti Mask Type Sensitivity
(X50ms)
295
Special Burg. 1Type Sensitivity
(X50ms)
296
Special Burg. 2 Type Sensitivity
(X50ms)
297
Silent Panic Type Sensitivity
(X50ms)
298
Special Fire Type Sensitivity
(X50ms)
299
Zone 1 Partition (1-8) 300
Zone 1 Partition (9-16) 301
Zone 2 Partition (1-8) 302
Zone 2 Partition (9-16) 303
Zone 3 Partition (1-8) 304
Zone 3 Partition (9-16) 305
Zone 4 Partition (1-8) 306
Zone 4 Partition (9-16) 307