Programming the Hunter-Pro series with a LED keypad 17
Parameter Address
OUT-1000-7 Partition (1-8) 441
OUT-1000-7 Partition (9-16) 442
OUT-1000-8 Partition (1-8) 443
OUT-1000-8 Partition (9-16) 444
IOR Partition 1 (1-8) 445
IOR Partition 1 (9-16) 446
IOR Partition 2 (1-8) 447
IOR Partition 2 (9-16) 448
IOR Partition 3 (1-8) 449
IOR Partition 3 (9-16) 450
IOR Partition 4 (1-8) 451
IOR Partition 4 (9-16) 452
IOR Partition 5 (1-8) 453
IOR Partition 5 (9-16) 454
IOR Partition 6 (1-8) 455
IOR Partition 6 (9-16) 456
IOR Partition 7 (1-8) 457
IOR Partition 7 (9-16) 458
IOR Partition 8 (1-8) 459
IOR Partition 8 (9-16) 460
IOR Partition 9 (1-8) 461
IOR Partition 9 (9-16) 462
IOR Partition 10 (1-8) 463
IOR Partition 10 (9-16) 464
IOR Partition 11 (1-8) 465
IOR Partition 11 (9-16) 466
IOR Partition 12 (1-8) 467
IOR Partition 12 (9-16) 468
IOR Partition 13 (1-8) 469
IOR Partition 13 (9-16) 470
IOR Partition 14 (1-8) 471
IOR Partition 14 (9-16) 472
IOR Partition 15 (1-8) 473
IOR Partition 15 (9-16) 474
IOR Partition 16 (1-8) 475
IOR Partition 16 (9-16) 476
IO8 Partition 16 (1-8) 477
IO8 Partition 16 (9-16) 478
Siren 1 Polarity/Active (1=Polarity
2=Active in Disarm)
479
Siren 2 Polarity/Active 480
Relay Polarity/Active 481
Smoke Polarity/Active 482
Parameter Address
ON/OFF Polarity/Active 483
Alarm Polarity/Active 484
Audio Control Polarity/Active 485
OUT-1000 -1 Polarity/Active 486
OUT-1000 -2 Polarity/Active 487
OUT-1000 -3 Polarity/Active 488
OUT-1000 -4 Polarity/Active 489
OUT-1000 -5 Polarity/Active 490
OUT-1000 -6 Polarity/Active 491
OUT-1000 -7 Polarity/Active 492
OUT-1000 -8 Polarity/Active 493
IOR -1 Polarity/Active 494
IOR -2 Polarity/Active 495
IOR -3 Polarity/Active 496
IOR -4 Polarity/Active 497
IOR -5 Polarity/Active 498
IOR -6 Polarity/Active 499
IOR -7 Polarity/Active 500
IOR -8 Polarity/Active 501
IOR -9 Polarity/Active 502
IOR -10 Polarity/Active 503
IOR -11 Polarity/Active 504
IOR -12 Polarity/Active 505
IOR -13 Polarity/Active 506
IOR -14 Polarity/Active 507
IOR -15 Polarity/Active 508
IOR -16 Polarity/Active 509
IO8 Polarity 510
Installer
Installer Code 511
Users
User 1 Settings (byte 1) (1=Code
Programming 2=Telephone
Programming 3=Date 4=Log View
5=Zone Bypass
6=Use Any Keypad 7=Auto Arming
Programming 8=Send Open/Close
reports by SMS)
512
User 1 Settings (byte 2) (9=Enable
Remote Control via PSTN)
513
User 2 Settings (byte 1) 514
User 2 Settings (byte 2) 515
User 3 Settings (byte 1) 516
User 3 Settings (byte 2) 517
User 4 Settings (byte 1) 518

Other manuals for Pima Hunter-Pro Series