EasyManua.ls Logo

Pioneer WYE012GMFI15RL User Manual

Pioneer WYE012GMFI15RL
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
RevisionA:1312030001,Contentupdated.
CoolingOnlyModelNumbers(Indoor+OutdoorUnits):HeatPumpModelNumbers(Indoor+OutdoorUnits):
WAE009AMFI15RL(WE009AMFI15CLD+AN009AMFI15RPD) WYE009AMFI15RL(WE009AMFI15HLD+YN009AMFI15RPD)
WYE009GMFI15RL(WE009GMFI15HLD+YN009GMFI15RPD)
WAE012AMFI15RL(WE012AMFI15CLD+AN012AMFI15RPD) WYE012AMFI15RL(WE012AMFI15HLD+YN012AMFI15RPD)
WAE012GMFI15RL(WE012GMFI15CLD+AN012GMFI15RPD) WYE012GMFI15RL(WE012GMFI15HLD+YN012GMFI15RPD)
WAE018GMFI15RL(WE018GMFI15CLD+AN018GMFI15RPD) WYE018GMFI15RL(WE018GMFI15HLD+YN018GMFI15RPD)
WAE024GMFI15RL(WE024GMFI15CLD+AN024GMFI15RPD) WYE024GMFI15RL(WE024GMFI15HLD+YN024GMFI15RPD)
Table of Contents
1. Precaution
2. Part Names And Functions
3. Specification
4. Dimension
5. Refrigerant Cycle Diagram
6. Wiring Diagram
7. Installation Details
8. Operation Characteristics
9. Electronic Function
10. Troubleshooting
11. Exploded View
12. Disassembly Instructions
WARNING
Installation MUST conform with local building codes or, in the absence of local codes, with the
National Electrical Code NFPA70/ANSI C1-1993 or current edition and Canadian Electrical
Code Part1 CSA C.22.1.
The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments.
Installation or repairs made by unqualified persons can result in hazards to you and others.
Failure to carefully read and follow all instructions in this manual can result in equipment
malfunction, property damage, personal injury and/or death.
This service
manual
is only for service engineer
'
s
to use
WAE-WYE SERIES SINGLE SPLIT DC INVERTER
AIR CONDITIONER / HEAT PUMP SYSTEMS
SERVICE MANUAL
Mono DC
Parker Davis HVAC International, Inc.
2260 NW 102nd Place, Doral, FL 33172
Ph: (305) 513-4488 info@pd-hvac.com
Question and Answer IconNeed help?

Do you have a question about the Pioneer WYE012GMFI15RL and is the answer not in the manual?

Pioneer WYE012GMFI15RL Specifications

General IconGeneral
RefrigerantR410A
Cooling Capacity12000 BTU/h
Voltage208-230V
Power SupplySingle Phase
Operating Temperature-5°C to 48°C

Summary

Precaution

Safety Precaution

General safety instructions to prevent injury and property damage during unit operation and installation.

Warnings

Critical warnings regarding installation, operation, electrical safety risks, and potential hazards.

Part Names And Functions

Model Names of Indoor/Outdoor units

Lists specific model numbers for indoor and outdoor units based on capacity.

Part names of Indoor/Outdoor units

Identifies and labels the physical components of indoor and outdoor units.

Functions of Indoor/Outdoor units

Details the various functions and features available for the indoor and outdoor units.

Dimension

Indoor Unit

Provides physical dimensions (W, D, H) for various indoor unit models.

Outdoor Unit Dimensions

Refrigerant Cycle Diagram

Wiring Diagram

Indoor Unit

Electrical wiring diagram for the indoor unit, showing component connections.

Outdoor Unit

Electrical wiring diagram for the outdoor unit, showing component connections.

Installation Details

Wrench torque sheet for installation

Specifies torque values for tightening fittings during installation.

Connecting the cables

Guidelines for selecting and connecting power cords based on appliance amperage.

Pipe length and the elevation

Details maximum pipe lengths and elevation differences allowed for system installation.

Installation for the first time

Step-by-step procedure for initial air and moisture evacuation and purging.

Operation Characteristics

Temperature

Defines operating temperature ranges for cooling, heating, and drying modes.

Electronic Function

Abbreviation

Defines technical abbreviations used for sensor readings and parameters.

Display function

Explains the meaning of indicator lights and symbols on the indoor unit display.

Main Protection

Describes various protection mechanisms and fault conditions for the unit.

Operation Modes and Functions

Fan only mode

Details operation when only the fan is active, with disabled temperature control.

Cooling Mode

Explains compressor and fan running rules for cooling operation.

Heating Mode

Describes compressor and fan running rules for heating operation.

Evaporator coil temperature protection

Details protection measures against low or high evaporator coil temperatures.

Auto-mode

Explains how the unit automatically selects cooling, heating, or fan-only based on temperature.

Drying mode

Describes the operation characteristics and limitations of the drying mode.

Forced operation function

How to enter and operate the unit in forced auto or forced cooling modes.

Timer function

Details the adjustable 24-hour timer functions for turning the unit on or off.

Sleep function mode

Explains the 7-hour sleep mode operation for cooling and heating cycles.

Auto-Restart function

Describes the unit's ability to resume previous settings after a power failure.

8°C Heating (Vacation Mode - Optional)

Optional feature to maintain room temperature at 8°C for preventing freezing.

Troubleshooting

Indoor Unit Error Display

Lists error codes and their corresponding LED status for the indoor unit.

Outdoor unit error display

Describes the blue LED indicator on the outdoor PCB and its meaning for unit status.

EEPROM parameter error diagnosis and solution(E0/F4)

Diagnoses and provides solutions for EEPROM parameter errors (E0/F4) involving PCB checks.

Indoor / outdoor unit's communication diagnosis and solution(E1)

Diagnoses and resolves communication errors (E1) between indoor and outdoor units, checking wiring and PCBs.

Zero crossing detection error diagnosis and solution(E2)

Diagnoses and resolves zero-crossing signal errors (E2) related to PCB and connection issues.

Fan speed has been out of control diagnosis and solution(E3)

Troubleshoots indoor fan speed errors (E3) by checking fan motor, wiring, and PCB.

Open circuit or short circuit of temperature sensor diagnosis and solution(E5)

Diagnoses and resolves temperature sensor errors (E5) due to open circuits, shorts, or faulty sensors.

Refrigerant Leakage Detection diagnosis and solution (EC)

Identifies and resolves refrigerant leakage errors (EC) by checking sensors, PCBs, and system integrity.

IPM malfunction or IGBT over-strong current protection diagnosis and solution(P0)

Addresses IPM or IGBT protection errors (P0) by checking wiring, fan, compressor, and PCBs.

Over voltage or too low voltage protection diagnosis and solution(P1)

Troubleshoots voltage protection errors (P1) by checking power supply, connections, and PCB.

High temperature protection of compressor top diagnosis and solution(P2)

Diagnoses and resolves compressor top high-temperature protection errors (P2) related to airflow and refrigerant.

Inverter compressor drive error diagnosis and solution(P4)

Resolves inverter compressor drive errors (P4) by checking wiring, IPM, fan, compressor, and PCBs.

Main Parts Check

Temperature sensor checking

Instructions for checking the resistance of various temperature sensors using a tester.

Compressor Checking

IPM and Motor Checks

IPM continuity check

Procedure to check IPM continuity by measuring resistance between specific terminals.

Indoor AC Fan Motor Resistance

Instructions for measuring the resistance of indoor AC fan motor windings.

Pressure On Service Port Cooling Chart