EasyManua.ls Logo

Pioneer WYE018GMFI15RL User Manual

Pioneer WYE018GMFI15RL
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
RevisionA:1312030001,Contentupdated.
CoolingOnlyModelNumbers(Indoor+OutdoorUnits):HeatPumpModelNumbers(Indoor+OutdoorUnits):
WAE009AMFI15RL(WE009AMFI15CLD+AN009AMFI15RPD) WYE009AMFI15RL(WE009AMFI15HLD+YN009AMFI15RPD)
WYE009GMFI15RL(WE009GMFI15HLD+YN009GMFI15RPD)
WAE012AMFI15RL(WE012AMFI15CLD+AN012AMFI15RPD) WYE012AMFI15RL(WE012AMFI15HLD+YN012AMFI15RPD)
WAE012GMFI15RL(WE012GMFI15CLD+AN012GMFI15RPD) WYE012GMFI15RL(WE012GMFI15HLD+YN012GMFI15RPD)
WAE018GMFI15RL(WE018GMFI15CLD+AN018GMFI15RPD) WYE018GMFI15RL(WE018GMFI15HLD+YN018GMFI15RPD)
WAE024GMFI15RL(WE024GMFI15CLD+AN024GMFI15RPD) WYE024GMFI15RL(WE024GMFI15HLD+YN024GMFI15RPD)
Table of Contents
1. Precaution
2. Part Names And Functions
3. Specification
4. Dimension
5. Refrigerant Cycle Diagram
6. Wiring Diagram
7. Installation Details
8. Operation Characteristics
9. Electronic Function
10. Troubleshooting
11. Exploded View
12. Disassembly Instructions
WARNING
Installation MUST conform with local building codes or, in the absence of local codes, with the
National Electrical Code NFPA70/ANSI C1-1993 or current edition and Canadian Electrical
Code Part1 CSA C.22.1.
The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments.
Installation or repairs made by unqualified persons can result in hazards to you and others.
Failure to carefully read and follow all instructions in this manual can result in equipment
malfunction, property damage, personal injury and/or death.
This service
manual
is only for service engineer
'
s
to use
WAE-WYE SERIES SINGLE SPLIT DC INVERTER
AIR CONDITIONER / HEAT PUMP SYSTEMS
SERVICE MANUAL
Mono DC
Parker Davis HVAC International, Inc.
2260 NW 102nd Place, Doral, FL 33172
Ph: (305) 513-4488 info@pd-hvac.com
Question and Answer IconNeed help?

Do you have a question about the Pioneer WYE018GMFI15RL and is the answer not in the manual?

Pioneer WYE018GMFI15RL Specifications

General IconGeneral
BrandPioneer
ModelWYE018GMFI15RL
CategoryAir Conditioner
LanguageEnglish

Summary

1. Precaution

1.1 Safety Precaution

To prevent injury to the user or other people and property damage.

1.2 Warning

Installation warnings and operational cautions.

2. Part Names And Functions

2.1 Model Names of Indoor/Outdoor units

Lists all available model combinations and their components.

2.2 Part names of Indoor/Outdoor units

2.3 Functions of Indoor/Outdoor units

3. Dimension

3.1 Indoor Unit

Provides the physical dimensions and mounting hole specifications for indoor units.

4.2 Outdoor Unit

4. Refrigerant Cycle Diagram

5. Wiring Diagram

5.1 Indoor Unit

Shows the internal electrical wiring schematics for the indoor unit across different models.

5.2 Outdoor Unit

6. Installation Details

6.1 Wrench torque sheet for installation

Specifies the correct torque values for tightening installation fittings.

6.2 Connecting the cables

Guides on selecting appropriate AWG wire sizes based on appliance amperage.

6.3 Pipe length and the elevation

Details the maximum allowable refrigerant pipe length and elevation differences.

6.4 Installation for the first time

7. Operation Characteristics

8. Electronic Function

8.1 Abbreviation

Defines key technical terms and sensor notations used in the manual.

8.2 Display function

Explains the indicators and symbols displayed on the indoor unit.

8.3 Main Protection

8.4 Operation Modes and Functions

Related product manuals