3-3
Virus SW 600 D
iS engine POH Supplement
SPOH-127-00-41-001
PAGE REV. 0
PAGE
SECTION 3
EMERGENCY PROCEDURES
APPROVED
3.3 GROUND EMERGENCIES
3.3.1 ENGINE FIRE DURING ENGINE START
A fire during engine start may be caused by fuel igniting in the fuel induc-
tion system. If this occurs, attempt to draw the fire back into the engine by
continuing to crank the engine.
1 Fuel Selector OFF
2 Starter KEEP CRANKING
3 Throttle Lever Full Forward
Once fire is estinguished:
4 LANE A/B switches OFF
5 Fuel pumps (main and aux) OFF
6 Master OFF
If flames persist, perform Emergency Ground Egress procedure.
3.3.2 EMERGENCY ENGINE SHUTDOWN ON GROUND
1 Throttle Lever IDLE
2 Fuel Selector OFF
3 LANE A/B switches OFF
4 Master Switch OFF
3.3.3 EMERGENCY GROUND EGRESS
1 Engine SHUTDOWN
2 Parking brake ENGAGED
3 Seat belts RELEASE
4 Airplane EXIT
While exiting the airplane, make sure evacuation path is clear of other air-
craft, spinning propellers, and other hazards. If the engine is left running, set
the parking brake prior to evacuating the airplane.