Installation, use and maintenance
I OPERATING CONDITIONS
I1 ENVIRONMENTAL CONDITIONS
TEMPERATURE min. 20 °C / max +60 °C
RELATIVE
HUMIDITY
max. 90%
LIGHTING The environment must conform to directive 89/654/EEC on work environ-
ments. In case of non-EU countries, refer to directive EN ISO 12100-2 §
4.8.6.
ATTENTION
The temperature limits shown apply to the pump components and must be
respected to avoid possible damage or malfunction.
I2 POWER CONSUPTION
NOTA Depending on the model, the pump must be fed by single-phase alternating
current whose nominal values are those indicated in the Table.
The maximum acceptable variations from the electrical parameters are:
Voltage:+/- 5% of the nominal value
Frequency:+/- 2% of the nominal value
ATTENTION Power from lines with values outside the indicated limits can damage the
electrical components.
I3 WORKING CYCLE
NOTE The motors are intended for continuous use. Under normal operating condi-
tions they can function continuously with no limitations
I4 PERMITTED AND NON-PERMITTED FLUIDS
PERMITTED
FLUDS
DIESEL WITH A VISCOSITY BETWEEN 2 AND 5.35 cST (AT A TEMPERATURE
OF 37.8 °C)
MINIMUM FLASH POINT (PM): 55 °C
Ref: EN5902010 dtd. 25/03/2010
NON
PERMITTED
FLUIDS
ALL THE FLUIDS NOT MENTIONED IN "ADMITTED FLUIDS"