Installation Instructions
Step 1. Connect the LRP Injector (LRP-101CH) and LRP Extender
(LRP-104CET) to ends of BNC terminated coaxial cable.
Stick the “Warning Sticker” on the coaxial cable.
Step 2. Connect Cat5/6 UTP cable to LRP-101CH and IEEE 802.3at compliant
PoE Switch or PoE Injector. If the PoE switch or PoE injector
is powered on already, then the PWR LED of LRP-101CH and
LRP-104CET should be lit up immediately.
Step 3. Connect Cat5/6 UTP cable to LRP-104CET and IEEE 802.3at/af
complied PoE IP camera or PoE Wireless AP.
Warning
The LRP-101CH accepts IEEE 802.3at equipment for optimal
power injection. The other non-standard PoE power devices may
cause the LRP-101CH to malfunction.
Type 2 One LRP-101CH with 48~56V power adapter and one LRP-104CET
with PoE power output
The LRP Injector is powered via the external power adapter. The IEEE 802.3at/
af compliant PoE PD will automatically be powered by the LRP Extender via
UTP.
802.3af/802.3at PoE
PoE IP Camera
LRP-104CET
Long Reach PoE Extender
Power over Coaxial
P1 P2 Fault
PWR
LNK
LRP IN
4
3
2
1
LRP-104CET
Ext.
PWR
10W 20W 30W 40W
PoE
Power
Usage
ACTLNK
PoE In-use
ON
ON
ON
ON
OFF
OFF
OFF
OFF
1
Port PoE
2
3
4
Long Reach PoE
Extender
1 2 3 4
OFF
Cat5e/6
PoE
PoE
PoE
PoE
Remote LRP Power over Coaxial
PoE Power Budget
60 watts~120 watts (max.)
Ethernet Switch
LRP-101CH
Long Reach PoE Injector
110-240V AC
AC-to-DC Adapter
60W~120W/48~56V DC IN
Long Reach Power over Ethernet
Functions
LRP Injector LRP Extender
LRP-101CH LRP-104CET
Power Input
Power adapter with 48~56V DC in
The LRP-101CH accepts up to 120W
external power input
BNC with DC power
over coaxial input
Power Output
BNC with DC power over coaxial
output
RJ45 with 802.3at/af
PoE output