RA100R/RA200KR Remote Alarm Programming
Note: For wiring, refer to: Figure 12 for RA200KR.
Figure 13 for RA100R
The following wiring scenario is being provided as a guideline only. The advantage to wiring
the CC Inputs as illustrated is to use the Reset switch in combination with the Test switch. The relays
can be wired in any combination. This is the way your system will be preprogrammed if supplied with
an RA100/RA200 alarm.
Programming:
1. Sets the tank conditions that must occur to activate the relays. Factory default conditions shown
below activate for SP1 (Above 95% volume) and SP2 (Above 90% volume).
Front Panel TMS Communicato
Config Rely Tank Configuration Relays Tank Triggers
Relays Relays
Leak Trig no.no.no Leak Trigger None - None - None
SP1 Trig 01.02.no Set Point #1 Trigger Relay #1 - Relay #2 - None
SP2 Trig 01.02.no Set Point #2 Trigger Relay #1 - Relay #2 - None
SP3 Trig no.no.no Set Point #3 Trigger None - None - None
H2O Trig no.no.no Water Trigger None - None
None
2. Chooses the CC Inputs (wired to RS2) that the relays will react to.
Front Panel TMS Communicato
Config Rely cc Configuration Relays Non-Hazardous Contact Closure Inputs
cc Trig Relays CC Trigger Relay Selects
1 02.no.no #1 Relay #2
None
None
2 01.02.no #2 Relay #1
Relay #2
None
3. Controls the behavior of a relay.
Front Panel
Config Rely Mode
Relay Normally FP Ack Delay Latch En
1 Off No None No
2 Off Yes None No
TMS Communicato
Configuration Relays Relay Mode
Relay Normal Contact State Allow Front Panel Acknowledgements Delayed Shutof
Latch Enable
#1 Off
None
#2 Off
None
4. Controls the behavior of a Contact Closure Input. Note: Only settings used for supporting the RS2 are
listed below. Do not change the factory default values for other unlisted settings.
Front Panel
Config cc Input
CC Input cc Enable Normally
1 Ack Open
2 Relay Open
TMS Communicato
Configuration Contact Closure Inputs Non-Hazardous Contact Closure Inputs
CC Input Contact Closure Enable Normally
#1 Acknowledge Open
#2 Relay Open
Contact Closure 1 Reset
Contact Closure 2 Test
Relay 1 Strobe
Relay 2 Horn