79
MAINTENANCE
Lubrication Guide
Check and lubricate all components at the intervals outlined in the 
Periodic Maintenance Chart beginning on page 74. Items not listed in 
the chart should be lubricated at the General Lubrication interval.
The a-arms and lower control arms are lubricated at the factory, and no 
additional lubrication will be needed. However, if these components are 
subjected to severe use, grease zerks have been provided for additional 
lubrication at the user's discretion.
Item Lube Capacity at 
Fluid Change
Inspection Procedure
Engine Oil PS-4 5W-50 
4-Cycle Oil
2 qt. (1.9 l) Maintain level in safe range 
on dipstick. See page 81.
Brake Fluid  DOT 4 Brake Fluid --- Maintain level between fill 
lines. See page 28.
Transmission Oil AGL Gearcase 
Lubricant & 
Transmission Fluid
32 oz. (948 ml) Maintain level at bottom of fill 
hole threads. See page 85.
Demand Drive 
Fluid 
(Front Gearcase)
Demand Drive 
Fluid
9 oz. (265 ml) Maintain level at bottom of fill 
hole threads. See page 86.
Front Prop Shaft 
Yoke
U-Joint Grease --- Grease fittings (3 pumps 
maximum) every 500 miles, 
before long periods of stor-
age, or after pressure wash-
ing or submerging.
Front Prop Shaft Yoke