70
TROUBLESHOOTING
Troubleshooting Symptoms
No Power at DC Receptacle
POSSIBLE LEAN
FUEL CAUSE
SOLUTION
Low or contaminated fuel Add fuel, or drain the fuel system and refuel
Kinked or plugged fuel tank
vent
Inspect and replace
Low octane fuel Drain the fuel system and refuel
Carburetor jetting incorrect Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
POSSIBLE RICH
FUEL CAUSE
SOLUTION
Incorrect fuel Drain the fuel system and refuel
Stopping / starting without
adequate warm-up
Allow the engine to warm up before operating and / or
stopping
Incorrect spark plug Inspect and replace with correct plug
Clogged air filter Inspect and clean or replace
POSSIBLE CAUSE SOLUTION
Is the fuse blown Replace the fuse.
Faulty generator Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual