B. Peristaltic Pump is Overfeeding Sanitizer or pH
If you are using the controller with a peristaltic pump, which
feeds slowly, it is better to have a very long feed cycle in order to
provide adequate sanitizer or pH control.
1. Timed Feed Mode = ORP and pH Switch #10 are OFF
2. Feed Cycle in Minutes = ORP Switch #8 is ON
pH Switch #7 is ON
3. Pool Mode = ORP Switch #7 is OFF
Spa Mode = ORP Switch #7 is ON
4. Choose your desired feed and cycle delay times from the fol-
lowing options.
Recommended Settings
ORP SWITCHES
Feed Cycle Switch Switch Delay Cycle Switch Switch
#3 #4 #5 #6
12 Minutes OFF ON 5 Minutes OFF OFF
pH SWITCHES
Feed Cycle Switch Switch Delay Cycle Switch Switch
#3 #4 #5 #6
8 Minutes ON ON 5 Minutes OFF OFF
Optional Settings
ORP SWITCHES
Pool Mode (#7 OFF) Spa Mode (#7 ON)
Feed Cycle Switch Switch Feed Cycle Switch Switch
#3 #4 #3 #4
12 Minutes OFF ON 2 Minutes OFF ON
16 Minutes OFF OFF 4 Minutes OFF OFF
24 Minutes ON ON 6 Minutes ON ON
32 Minutes ON OFF 8 Minutes ON OFF
Delay Cycle Switch Switch Delay Cycle Switch Switch
#5 #6 #5 #6
2 Minutes OFF ON 1 Minutes ON ON
5 Minutes OFF OFF 2 Minutes OFF ON
10 Minutes ON OFF 5 Minutes OFF OFF
20 Minutes ON ON 10 Minutes ON OFF