EasyManua.ls Logo

Polaris Watermatic C-660 - Peristaltic Pump Settings

Polaris Watermatic C-660
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B. Peristaltic Pump is Overfeeding Sanitizer or pH
If you are using the controller with a peristaltic pump, which
feeds slowly, it is better to have a very long feed cycle in order to
provide adequate sanitizer or pH control.
1. Timed Feed Mode = ORP and pH Switch #10 are OFF
2. Feed Cycle in Minutes = ORP Switch #8 is ON
pH Switch #7 is ON
3. Pool Mode = ORP Switch #7 is OFF
Spa Mode = ORP Switch #7 is ON
4. Choose your desired feed and cycle delay times from the fol-
lowing options.
Recommended Settings
ORP SWITCHES
Feed Cycle Switch Switch Delay Cycle Switch Switch
#3 #4 #5 #6
12 Minutes OFF ON 5 Minutes OFF OFF
pH SWITCHES
Feed Cycle Switch Switch Delay Cycle Switch Switch
#3 #4 #5 #6
8 Minutes ON ON 5 Minutes OFF OFF
Optional Settings
ORP SWITCHES
Pool Mode (#7 OFF) Spa Mode (#7 ON)
Feed Cycle Switch Switch Feed Cycle Switch Switch
#3 #4 #3 #4
12 Minutes OFF ON 2 Minutes OFF ON
16 Minutes OFF OFF 4 Minutes OFF OFF
24 Minutes ON ON 6 Minutes ON ON
32 Minutes ON OFF 8 Minutes ON OFF
Delay Cycle Switch Switch Delay Cycle Switch Switch
#5 #6 #5 #6
2 Minutes OFF ON 1 Minutes ON ON
5 Minutes OFF OFF 2 Minutes OFF ON
10 Minutes ON OFF 5 Minutes OFF OFF
20 Minutes ON ON 10 Minutes ON OFF
26

Related product manuals