X-RAY AND GAMMA RADIATION PERSONAL DOSIMETERS
РМ1621
Models:
РМ1621
РМ1621А
РМ1621М
РМ1621МА
OPERATING MANUAL
Question and Answer IconNeed help?

Do you have a question about the Polimaster PM1621 and is the answer not in the manual?

Polimaster PM1621 Specifications

General IconGeneral
BrandPolimaster
ModelPM1621
CategoryMeasuring Instruments
LanguageEnglish

Summary

1 DESCRIPTION AND OPERATION OF THE DOSIMETER

1.1 Application Range

Describes the purpose and models of the X-ray and gamma radiation personal dosimeter.

1.2 Delivery kit

Details the contents of the dosimeter's delivery kit, including the device, accessories, and documentation.

1.3 Specifications

Encompasses operating modes, measurement ranges, error margins, and response times of the dosimeter.

1.4 Design and theory of operation

Explains the internal components, block diagram, and working principles of the dosimeter.

2 USE OF THE DOSIMETER

2.1 General guidelines

Offers general recommendations for using the dosimeter, including checking the delivery kit and protecting it from damage.

2.2 Safety instructions

Outlines safety instructions for operating the dosimeter, especially when using radioactive sources.

2.3 Preparation for use

Details the steps required to prepare the dosimeter for use, including unpacking and battery insertion.

2.4.1 Dosimeter operation modes

Lists and describes the various operating and indication modes available on the dosimeter.

2.4.2 Selection of an indicated parameter

Explains how to switch between different display modes for parameters like DER, DE, and dosimeter number.

2.4.3 DER measurement mode

Details the DER measurement mode, including displayed values and scale indications.

2.4.4 DE measurement mode

Describes the DE measurement mode, including displayed values and accumulation time.

2.4.5 Settings mode

Explains how to enter the settings mode to configure threshold values and reset parameters.

2.4.6 The dosimeter's number indication mode

Describes the mode for displaying the dosimeter's unique identification number and production details.

2.4.7 Mode of data transmission to PC

Details the process of transmitting dosimeter data to a PC via IR communication.

2.4.8 Search mode (PM1621M, PM1621MA)

Explains the search mode for detecting and locating gamma radiation sources using alarms.

2.4.9 Indication mode of audio alarm state (PM1621M, PM1621MA)

Describes how to control and indicate the state of the audio alarm, including sound level adjustment.

2.4.10 Indication mode of vibro alarm state (PM1621M, PM1621MA)

Explains how to control and indicate the state of the vibro alarm on the dosimeter.

2.4.11 Partial or critical battery discharge indication mode

Details the indication modes for partial and critical battery discharge and the dosimeter's response.

3 MAINTENANCE

3.1 Maintenance

Covers preventive services, battery replacement, and performance checks for the dosimeter.

3.2 Preventive services

Details preventive actions like external examination, dusting, and decontamination.

3.3 Battery replacement

Provides step-by-step instructions for replacing the dosimeter's battery.

4 TROUBLESHOOTING

5 VERIFICATION METHOD

5.1 Introduction

Introduces verification procedures for PM1621 models, covering metrological services and manufacturer checks.

5.2 Verification procedures and tools

Lists the necessary procedures and tools for verifying the dosimeter's performance.

5.3 Verification officers' qualification requirements

Specifies the qualification requirements for personnel conducting verification procedures.

5.4 Safety requirements

Outlines the obligatory safety requirements for verification, especially concerning radioactive sources.

5.5 Verification conditions

Details the environmental conditions required for performing dosimeter verification.

5.6 Pre-verification procedure

Describes the preparatory procedures to be followed before the actual verification process.

5.7 Verification procedure

Details the overall process of verifying the dosimeter.

5.7.1 External examination of the instrument

Details the external examination process to ensure the instrument meets specified requirements.

5.7.2 Carrying out verification (testing)

Outlines the steps for carrying out the verification (testing) of the dosimeter's operability.

5.7.3 Metrological examination

Describes the metrological examination, including DER measurement error calculation.

5.7.3.2 DE measurement main relative measurement error

Explains how to calculate the main relative measurement error for DE.

6 STORAGE AND SHIPPING

6.1 Storage and Shipping Conditions

Covers conditions for shipping and storing dosimeters, including packaging and environmental requirements.

7 WARRANTY

7.1 Warranty Terms and Conditions

Details the manufacturer's warranty, its duration, exclusions, and repair policies for the dosimeter.