PM1701M
ALARMING RATEMETER
Operation Manual

Questions and Answers:

Polimaster PM1701M Specifications

General IconGeneral
BrandPolimaster
ModelPM1701M
CategoryMeasuring Instruments
LanguageEnglish

Summary

GENERAL DESCRIPTION

Delivery Kit

Lists all items included in the PM1701M package, such as the instrument, accessories, manual, and software.

Specifications

Details technical specifications of the PM1701M, including detector type, sensitivity, measurement ranges, and environmental resistance.

Battery Installation

Provides step-by-step instructions for battery installation and notes on low battery warnings.

Design. Control Buttons and Display

Describes the instrument's physical components, including the telescopic pole, control buttons, LCD display, and connection ports.

OPERATION

Turning the Instrument ON/OFF

Explains the procedure for powering the instrument on and off, including initial self-checks and calibration.

Operating Modes

Outlines the instrument's various operational modes: Self-Check, Background Calibration, Search Mode, and Settings.

Self-Check

Details the automatic self-test sequence performed on startup to verify instrument components.

Background Calibration

Explains background radiation measurement for setting alarm thresholds using a specific formula.

Search Mode. Detection and Location of Radiation Sources

Guides users on searching for radiation sources, interpreting signals, and factors affecting sensitivity.

Settings

Covers instrument configuration options, allowing adjustment of parameters like coefficient n and alarms.

Setting the Coefficient n

Guides users on setting the coefficient 'n' to adjust the instrument's alarm sensitivity.

Switching ON/OFF Audible and Headphones Alarm

Details how to enable or disable the audible and headphone alarms via the settings menu.

COMMUNICATION WITH PC. DATA LOGGING, PARAMETERS SET-UP

Information (Data Logging) System

Explains PC software for data collection, user ID assignment, and downloading operational history.

Instrument/Program Settings

Describes configuring instrument parameters via PC, including alarms, logging intervals, and password settings.

MAINTENANCE

TROUBLESHOOTING

CALIBRATION TEST PROCEDURE (REFERENCE)

General

Provides an overview of the calibration procedure, emphasizing qualified facilities and regulatory compliance.

Safety precautions

Outlines essential safety measures for handling radioactive materials and radiation during calibration.

Test conditions

Specifies the required environmental conditions for calibration, including temperature, humidity, and pressure.

Preparation for calibration tests

Details necessary preparations before calibration, focusing on studying the operating manual.

Calibration procedure

Describes the step-by-step process for instrument calibration, including checks and metrological performance.