11. Installer Menus
There are 2 Installer Menus which can be accessed by pressing
and holding the either :
Programme key
(
) Programmes 1 to 12
or the escape key ( ) programmes 21 to 33
Installer Programmes 1 to 12
Default value & other possibilities
01 Deg: Type of degrees displayed
°C Celsius
°F Fahrenheit
02 __:__ Selection of the clock
24H (24:00)
12H (12:00 AM /PM)
03 DST Automatic Daylight Summetime
YES or NO
04 AirS: Instantaneous value of ambient sensor
05 Airc: Calibration of the internal probe
The calibration can done after 1 working
day with the same setting temperature in
accordance with the following description:
Put a thermometer in the room at 1.5M
distance from the floor (like the thermostat) and
check the real temperature in the room after 1
hour.
When you enter on the calibration parameter
nois displayed on the right to indicate no
calibration has made.
To enter the value read on the thermometer,
use the (-) or (+) keys to enter the real value.
Once, press (OK) to confirm.
The message Yes” should be displayed, the
value will be stored in the internal memory.
If you need to erase a calibration press on the
escape key ( ).
The old value will be erased and the message
nowill be displayed.
Note: Only the heating element managed
by the thermostat must be run during the
complete step of the calibration.
06 EXTS – Instananeous value of floor sensor
08 HGFrost protection temperature 10deg C
09 ITCS:
The Intelligent Temperature Control System
or Optimun start programme will activate
your system in advance to assure the desired
temperature at the hour programmed
08 Clr ALL: Factory setting
All parameters (Time, program...) will be
reloaded with default setting values.
Note Ensure you that you have all necessary
elements to re-start before use this function.
09 Hyst: Hysteresis value
0.C or 1°C
10 Software version
Vers __._
11 End: Exit the Installers menu
Press (OK) key to exit installater menu and
return to normal operation.
Default value & other possibilities
21 out NC/ NO - Type of actuator used ,set as
normally closed (NC)
22 PUMP
YES/NO Pump exercise programme
every 12 hrs
23- Settings for External sensor as previously
25 described
26 Type HYS/ rEGType of regulation ,
hysteresis /
proportional band
27 HYSt
0.05/1.1 Hysteresis band gap
28 tON
02 = relay ON anti short cycle in minutes
29 tOFF
02= relay OFF anti short cycle in minutes
31 CP
0.00 = advanced parameter if internal
sensor id heated by a heating element ,
compensation value in deg c at100% power
32 Clr EEP +hold OK = will reset non volatile
memory programs to factory
33 End +OK to exit the Installer Menu
Installer menus 21 to 33