CHECK THE WATER PARAMETERS
At the beginning of any new season and at the moment of installing the device, check and correct the
following points imperatively:
Stabilized between 7,0 and 7,4.
Important : whatever is the system of chemical process, the efficiency of the chlorine decreases
very quickly with the increase of the pH and the scale deposits appear all the more fast as the
pH rate is high or instable.
The water must be correctly balanced (TAC, TH) :
➢ The TAC (Permanent Hardness) indicates the bicarbonates rate dissolved in
water.
➢ The TH indicates the hardness of water, it means the content in salts of calcium
or magnesium dissolved in water. The hardness of water should not exceed
60°f.
Be careful : the non compliance with these recommendations will involve inevitably a misuse of the device,
which entails the annulations of the guarantee.
Your device is now ready.
Important:
For the protection and longevity of equipments of your pool, it is imperative to respect literally the instructions of use
mentioned in this manual. The presence of an amperometric chlorine regulation, of a pH production controller or a pH
regulation do not exempt from the strict respect of the instructions and do not have authority to eliminate the risks and
damages but only to limit them. Indeed, in spite of the smooth running of a control or regulation device, other factors
may cause damage, in particular:
- an insufficient ventilation in case of covered pool (shelter, tarpaulin, cover)
- A maintenance default of analysis probes (calibration, addition of the consumable…)
- Manual processing of supplements excessive or not adapted
- the non compliance with the instructions of use described in the present user manual
These isolated or organized factors will tend to cause oxidation on all metallic parts and of automatic cover pins and
slats, telescopic shelters and heat exchangers can lead to irreversible deterioration (discoloration) of the pool lining.
Therefore, if the manufacturer’s responsibility was engaged for a malfunction of the control or regulation device, it
would be limited to the repair or the replacement of the product free of charge. Then, it is strongly recommended to
check the levels of chlorine and pH each week with your usual analysis kit.