1.5.6. Filtration
In this system, the ltration process is based on water ozonation. The water is sucked by the skim-
mer lter and then mixed with ozone by the injector. After that, the water returns to the SPA bath
through the ozone jet. The ltration process consists on two steps. The rst step lasts 1 minute,
water pump work at the highest speed, while the heater is on. When one pump works in a low gear
along with the water ozonator and the electric heater. The duration of ltration depends on the time
setting. Filtration mode is indicated by this special icon
on the display. Filtration process can be
suspended (the ltration icon is blinking on the display) by switching on any of massage pumps.
Filtration will return to its normal mode after 40 minutes after user last operations. Switching the
lighting on does not suspend the ltration process.
Setting ltration parameters:
Press the ltration button
The display will show Fdxx, where xx stands for the ltration duration from 0 to 12 hours.
If xx is set on 0, the ltration does not work
Filtration duration can be changed with these arrows
and the selected value is con r-
med by pressing the ltration button
The blinking ltration start time will appear on the display
Changes are made with these arrows
and con rmed by using the ltration button
After con rming the selected minutes by pressing the ltration button, the controller memorizes
the setting and returns to its normal work. If no button is pressed for longer than 5 seconds during
the setting procedure, the controller will quit the ltration setting menu and will not remember any
changes.
1.5.7. Fast ltration (Boost)
The “boo” function enables to make faster water ltration. During this function, all the pumps work for
1 minute. Additionally, pump works in a fast gear for 45 minutes along with the ozonator. The heater
works normally during the fast ltration process. After switching this function on, the „boo” sign ap-
pears on the display and is present until this function is nished. Fast ltration process is triggered
by pressing and holding the pump 1 button for 10 seconds. This function can be switched off earlier
by starting any other pumps.
1.5.8. Setting the water temperature
To set the water temperature, press the arrow buttons on the control panel.
The selected temperature does not have to be con rmed, but only set. The display, after 5 seconds
from the last pressing, will return to the previous status and start showing the current water tempe-
rature. The controller maintains the set temperature with an accuracy of ± 0,5°C (1°F). If the water
temperature is lower than that previously set, the controller will start the heater and low gear pump
( ltration circuit) and keep it on until the water reaches its required temperature. If the economy
mode is on
the controller keeps the water temperature lower by 10 degrees than that previous
ly set. After the economy mode is off, the controller returns to maintaining the previou set tempera-
ture.