9
PORA ELECTRIC MACHINERY CO.,LTD.
PR-DTC-4000C
PR-DTC-4000CP
Tension signal output
0~10V
E/P regulator
4~20mA
Power output
for tension detector
5V 100mA
Service power
DC 12V 500mA
power output
5V
PB+
PB-
V_OUT
GND
S1
S1
EP
TG-GND
TG+
+5V
SIG-
SIG+
SIG-
SIG+
Zero span
adjustment
Zero span
adjustment
장력검출기 (좌측)
장력검출기 (우측)
E
220V
220V
AC 220V±10% 60Hz
Power supply
D종 접지 (100Ω 이하)
FG on metal plate
250V 8A
+
외부장력설정
TG
TG_GND
10KΩ 1KΩ
0.1Ω
0.1Ω
0.1Ω
DC 24V 4A
Powder clutch/brake
clutch/brake
A
B
PA+
PA-
0.1Ω
12V
EX+
EX-
ZERO
AUTO
1.4KΩ Photo coupler
OUT
ZERO
AUTO
OUT
GND
5V
GND
EMERGENCY
EMERGENCY
on onoff
OUT OFF OUT ON OUT OFF OUT ON
on onoff
on onoff
AUTO AUTOMANU
Pressing the button
(One pulse contact)
Pressing the button
(One pulse contact)
Pressing the button
(One pulse contact)
Pulse
mode
Hold
mode
onoff off off
EMS
OFF
EMS
ON
EMS
OFF
EMS
OFF
EMS
ON
on
Pressing the button
(One pulse contact)
Zero Calibration Zero Calibration
Pulse
mode
Hold
mode
Pulse
mode
Hold
mode
on onoff
OUT OFF OUT ON OUT OFF OUT ON
on onoff
on onoff
AUTO AUTOMANU
Pressing the button
(One pulse contact)
Pressing the button
(One pulse contact)
Pressing the button
(One pulse contact)
Pulse
mode
Hold
mode
onoff off off
EMS
OFF
EMS
ON
EMS
OFF
EMS
OFF
EMS
ON
on
Pressing the button
(One pulse contact)
Zero Calibration Zero Calibration
Pulse
mode
Hold
mode
Pulse
mode
Hold
mode
Pulse
mode
Hold
mode
on onoff
OUT OFF OUT ON OUT OFF OUT ON
on onoff
on onoff
AUTO AUTOMANU
Pressing the button
(One pulse contact)
Pressing the button
(One pulse contact)
Pressing the button
(One pulse contact)
Pulse
mode
Hold
mode
onoff off off
EMS
OFF
EMS
ON
EMS
OFF
EMS
OFF
EMS
ON
on
Pressing the button
(One pulse contact)
Zero Calibration Zero Calibration
Pulse
mode
Hold
mode
Pulse
mode
Hold
mode
Pulse
mode
Hold
mode
< OUT >
< AUTO >
< ZERO >
on onoff
OUT OFF OUT ON OUT OFF OUT ON
on onoff
on onoff
AUTO AUTOMANU
Pressing the button
(One pulse contact)
Pressing the button
(One pulse contact)
Pressing the button
(One pulse contact)
Pulse
mode
Hold
mode
onoff off off
EMS
OFF
EMS
ON
EMS
OFF
EMS
OFF
EMS
ON
on
Pressing the button
(One pulse contact)
Zero Calibration Zero Calibration
Pulse
mode
Hold
mode
Pulse
mode
Hold
mode
Pulse
mode
Hold
mode
< EMS >
4) Function of Input Contacts
EMS: EMS ON/OFF is operated.
·Hold mode: ON (EMS), OFF (No setup)
·Pulse mode: Whenever the switch is pressed, ON/OFF is
alternated.
OUT: ON/OFF of output is set.
·Hold mode: ON (Output on), OFF (Output off)
·Pulse mode: Whenever the switch is pressed, ON/OFF is
alternated.
ZERO: Zero setup can be done.
·Hold mode: ON (Zero Calibration), OFF (No Setup)
·Pulse mode: When the switch is long pressed, zero setup can
be done.
AUTO: Automatic and manual operations are switched.
·Hold mode: ON (Auto), OFF (Manual)
·Pulse mode: Whenever the switch is pressed, automatic and
manual operations are alternated.
Four Terminal Contacts
Contact point for terminal has 4 ponts and according to setting, you can set hold mode or pulse mode.
(※It can be used only when the REMOTE operation is activated.)
Remote Input Circuit
※Note
· When using a remote in hold mode, operation button
at the front is not working.
· When using a remote in plus mode, operation button
at the front is working partially.