6- ENG
D22721
MAINTENANCE
Lubrication
Air tools require lubrication throughout the life of the tool. The air motor and bearing uses
compressed air to power the tool. Because moisture in compressed air will rust the air
motor, you must lubricate the motor daily. An inline oiler is recommended.
To lubricate the air motor manually:
●
Remove chisel.
●
Disconnect the tool from the air supply holding it so the air inlet
faces up.
●
Depress the trigger and place one to two drops of air tool oil in the
air inlet Depressing the trigger helps circulate oil in the motor.
NOTE: Use SAE #10 weight oil if air tool oil is not available.
●
Connect the tool to an air source, cover the exhaust end with a towel
and run for a few seconds.
Any excess oil in the motor is immediately expelled from the
exhaust port. Always direct exhaust port away from people
or objects.
Failure to lubricate the tool at the air inlet will void your
warranty.