EasyManua.ls Logo

POSEIDON Xstream Series - Page 27

POSEIDON Xstream Series
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XSTREAM USER MANUAL
Maximum Operational depth Certied to 200 m (656 ft)
Typical Work of Breathing
50m on air, 62.5 l/min
1.5 J/l (see diagrams below)
Typical Work of breathing
200m on Trimix, 62.5 l/min
1.7 J/l (see diagrams below)
Approved gas Dive
Deep
manufactured before 2015 Air
Deep
manufactured after 2016 Nitrox
(EAN 40 max)
Duration Air / EAN 50 /
Oxygen
Deco Air / Oxygen
Maximum working pressure 300 bar (4351 psi)
Cold water performance Exceeding EN 250 requirements for
cold water use
Approvals Type Approved acc. to EU Directive
Personal Protective Equipment 89/686/EEC
Applicable Performance
Standards
EN 738-1, clause 6.6, 6.6.2
NORSOK U-101 clause 5.2-5.5, 5.9
EN 250:2000
Cleaned to hydrocarbon levels
< 50mg/ m2 & particle level X
Dive No
Deep No
Duration Yes
Deco / Oxygen Yes
O-ring materials Dive Nitrile, EPDM
Deep Nitrile, EPDM
Duration Viton, EPDM
Deco / Oxygen Viton, EPDM
25