XSTREAM USER MANUAL
Leakages at extremely
cold conditions
Incorrect orings Have the regu-
lator serviced
by an autho-
rised dealer,
require o-ring
replacement
There is a sound from
the regulator
The sound is
occurring even
while diving
Incorrect lubri-
cants have been
used
Have the regu-
lator correctly
lubricated by an
authorised dealer
Gas vents from 2nd
stage on opening the
cylinder valve
Does it
stop within 1-2
seconds?
If yes, it is normal that max.
3 litres of air is used to engage
the servo-mechanism
If no, the cracking pressure is too
low, which increases the risk for
free-ow
31