:: 20 XSTREAM
USER MANUAL :: ENGLISH
M I S C E L L A N E O U S
M I S C E L L A N E O U S
Approved gas mixes for Dive:
Maximum level of:
Oxygen 21% by volume
CO 15 ppm
CO2 500 ppm
Water dew point -35ºC (-31°F)
Lubricants (droplets/mist) 0.5 mg / m
3
Water 25 mg / m
3
Maximum Operational
depth
Certified to 200 m (656 ft)
Typical Work of Brea-
thing
50m on air, 62.5
l/min
1.5 J/l (see diagrams below)
Typical Work of brea-
thing
200m on Trimix,
62.5 l/min
1.7 J/l (see diagrams below)
Approved gas Dive Air
Deep Air / Trimix
Duration Air
/ EAN 50 /
Oxygen
Deco Air / Oxygen
Maximum working
pressure
300 bar (4351 psi)
Cold water perfor-
mance
Exceeding
EN 250 requirements for
cold water use
Approvals Type
Approved acc. to EU Direc-
tive Personal Protective Equipment
89/686/EEC
Applicable Performan-
ce Standards
EN 738-1, clause 6.6, 6.6.2
NORSOK U-101 clause 5.2-5.5, 5.9
EN 250:2000
Cleaned
to hydrocar-
bon
levels < 50mg/
m2 & particle level X
Dive No
Deep No
Duration Yes
Deco / Oxygen Yes
O-ring materials Dive Nitrile, EPDM
Deep Nitrile, EPDM
Duration Viton, EPDM
Deco / Oxygen Viton, EPDM
TECHNICAL DATA
Maximum level of:
Oxygen 99.95% by volume
CO 2 ppm
CO2 500 ppm
Water dew point -45ºC (-50°F)
Lubricants (droplets/mist) 0.5mg/ m
3
Water 25 mg/ m
3
Gaseous hydrocarbons 15 ppm
Condensed hydrocarbons 0.1 mg/m
3
Solid particles 2 microns
Approved gas mixes for Xstream Deco/Duration/
Duration90/Oxygen:

Related product manuals