F U N C T I O N
Oxygen alert and oxygen handling recommendations in this
manual applies to all parts and products intended for use
with greater than 21% oxygen by volume.
All accessories and other SCUBA equipment connected to
Xstream must be approved by the manufacturer for use with
the same oxygen content which is used with the Xstream.
Cylinder valves must always be opened carefully and slowly,
to avoid pressure shocks.
Oxygen can cause serious medical effects or even death
if used incorrectly. Use recognised tables for oxygen
exposure.
Xstream Oxygen EN 144-3/Deco/Deco EN 144-3 is approved
for oxygen service directly from the box, i.e. it is cleaned
to NASA Specification [1] Cleaning test Level 100 (particle
contamination) and NVR levels less than ASTM G63 Level C,
<50 mg/m2 (hydrocarbons).
Xstream Duration/Duration EN 144-3 is cleaned to the same
level as Xstream Deco Regulators and all other equipment
for oxygen service must be identified as such
Xstream Oxygen EN 144-3/Deco/Deco EN 144-3 and Dura-
tion/Duration EN 144-3 must never be used with contami-
nated gas. Refere to Breathing gas section.